Operation Manual

7
PRIMETECH ENGINEERING
7/43
1. Overview
This operation manual describes functions and procedures for the GigE Vision interface SWIR1.3M/0.3M (B/W) CMOS
Camera (B/W).
1.1. Characteristics
Interface
Compliant with the GigE Vision interface. Supports DC12V input using the attached AC adapter.
Resolution
The number of effective pixels of the camera module is 1280(H) x 1024(V) for PXG130SP/PXG130S,
640(H) x 512(V) for PXG030SP/PXG030S.
Diverse mode setting
The following modes can be set by sending commands from the host device.
Image acquisition mode (Continuous / Multi Frame)
Shutter function: Normal/triggered shutter
Output bit length switching
Read mode: Normal / Vertical decimation / Horizontal decimation / Image cropping (ROI)
Frame rate control
Exposure Time control
Gain control
Black level control
Gamma correction
User set control
Image reverse function (H/V)
Binarization function
Cross line display
Test pattern display
Sensor temperature display / control function (Temperature control is PXG130SP / PXG030SP only)
Defect pixel correction
Edge enhancement
Black and white inversion