Check-In to OneVue
A Smart-Sync Bridge checks-in to your OneVue account and obtains UTC time from a NTP Server at a daily system specified interval.
Note:
During No Network Mode, the bridge does connect to an Ethernet or Wi-Fi network, therefore cannot check-in to OneVue. No
Network mode is for use only when a network is not available at the facility, commonly during new construction.
When the device check-in button is pressed, a manual check-in is initiated.
When the check-in button is pressed, the device LCD displays its connection sequence.
Number 1 displayed - radio powered on
Numbers 12 displayed - connected to facility's Ethernet or Wi-Fi network
Numbers 123 displayed - connected to NTP Server and obtained UTC Time
Numbers 1234 displayed - connected to OneVue; sends Smart-Sync Clock statuses to OneVue and downloads update pending settings
During an active check-in connection, additional pressing of the check-in button is ignored.
If a check-in fails, all clock data is stored in the device's non-volatile memory; up to a maximum of 1400 clocks.