Install Guide

DRAFT
7. Select Continue.
8. Enter Name of the Transceiver. The name commonly identifies its install location and type of Transceiver (main or repeater).
9. Verify Call Sign.
Call Sign displayed: Verify the Call Sign is the same as the supplied FCC/IC Information Form. If not correct, update.
Call Sign not displayed: Enter the Call Sign located on the supplied FCC/IC Information Form. A Transceiver will not transmit
(broadcast) without a valid Call Sign.
10. Select a Time Zone (main Transceiver only). The time source detected is displayed (GPS or NTP). This setting does not apply to a
Repeater Transceiver, which receives the main Transceiver time zone and synchronized time over its configured Channel
(receive) number.
11. Power-on Transmit Schedule: Sets the duration of time the Transceiver transmits (broadcasts) a signal when first powered on.
Default to 8 hours. When power-on time period ends, the Transceiver reverts to its Normal Transmit Schedule.
12. Normal Transmit Schedule: Sets the frequency the Transceiver transmits (broadcasts). List below are the default settings and
recommended by Primex.
Transceiver with internal antenna: By default, a Transceiver with internal antenna: transmits (broadcasts) its synchronized time
continuously to the system clocks and devices. Default setting 0 to 0.
13. Channel section settings for the Main Transceiver only. Set the below settings.
Channel (broadcast): Required to be set to the Channel number located on the FCC/IC Information Form.
16