REGULATION STOP: If the high voltage threshold is conrmed via
REGULATION FLOAT (per the potenometer/baery regulaon set
screw seng), the AIR shis to REGULATION STOP and stops charging
the baery; blades will slow dramacally or stop. The turbine remains
in regulaon unl the baery voltage drops below the regulaon set
point (cut-in voltage). The blades then resume spinning in response to
the available wind.
In REGULATION STOP, the turbine’s LED will blink approximately once
per second or 3 mes per second depending on the code revision level
of your turbine.
When the baery voltage drops to the cut-in voltage; which is slightly
lower than voltage set point, AIR re -enters REGULATION FLOAT and
subsequently POWER MODE. The dierence between the two values is
termed “hysteresis” and is purposely done to prevent the turbine from
bouncing in and out of a single regulaon set point.
OPERATION SUMMARY
(REGULATION MODES—connued)
REGULATION FLOAT: When the baery voltage set point has
been reached, the turbine enters a temporary mode called REGULA-
TION FLOAT where the voltage is briey monitored to conrm the high
voltage readings. Depending on the code revision, the LED will either
blink erracally (quick blinks followed by long blinks) or blink approxi-
mately 3 mes per second. Aer a short me, the turbine will shi to
REGULATION STOP or back to POWER MODE (depending on the
baery voltage readings).
OPEN CIRCUIT CONDITIONS: AIR spins freely if disconnected from an
electrical load (i.e. baery). This results in a cycle of rapid blade speed increas-
es followed by rapid braking. This accelerates turbine wear and is non-
producve. Primus Wind Power recommends:
• Using a properly installed switch to turn AIR o for short periods of me
• Lowering the turbine completely or securing the blades to prevent rotaon if
the turbine will be shut down for an extended period of me
BASIC LED (light) FUNCTION:
• LED at “power up” mode will have two slow “BLINKS” (this should be
veried prior to raising tower )
• LED “SOLID” indicates “operaon or charging mode”
• LED “FAST” blink indicates “overspeed protecon or regulaon mode”
CONTACT PRIMUS WIND POWER TECH SUPPORT FOR FURTHER ASSISTANCE
should none of these LED funcons be acve!
IMPORTANT: The AIR turbine may not charge if baery open circuit voltage
drops below 10.5V (12V system), 21V (24V) and 42 V (48V system) as the internal
charge control circuit may not recognize that the baery is connected to the turbine
f when connected voltage drops further indicang a totally “dead” baery.