AIR Owner's Manual
AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc. AIR Owner’s Manual 3-CMLT-2020-A 46
APPENDIX: A
Lithium Ion Baery Technical Bullen
FROM: Primus Wind Power Engineering Department
RE: Potenometer Adjustment of the Regulaon Voltage for all AIR Wind Turbines and all Baery Types (including Lithium Ion baeries)
The AIR turbine connually monitors baery voltage (as a bulk charging
source) and compares it to the voltage regulaon set point. The voltage
regulaon sengs are preset at the factory to the values illustrated with-
in the table in this document. These values are adjustable for individual
applicaons. The AIR factory preset point is generally acceptable for most
sealed and ooded lead acid baery types. Most lithium ion (LI) baeries
are designed to be “drop in” replacements for lead acid baeries. Howev-
er, some LI baeries have a lower recommended charge voltage. Refer to
your baery manual for the recommended bulk charge voltage. Using
the AIR manual or informaon below, please make the necessary adjust-
ments to the regulaon voltage set point per the baery manual ulized.
The AIR turbines will funcon properly using all baery types if the above
consideraons are taken into account. Adjustments to the regulaon
voltage set point may be avoided considering the following - the larger
the baery bank and more consistent voltage load, the less likely the
need for any adjustments to the regulaon voltage set point.
All LI Baeries have a baery management system and should disconnect
if the charging voltage is too high to protect the baery. If the LI baery is
disconnecng during use, please refer to steps below to adjust the regula-
on voltage set point. It is also strongly recommended with LI baeries as
well as all baery types that when the turbine is le unaended and in-
curs no load for extended periods of me, the stop switch should be tog-
gled to the STOP/OFF posion for safety.
In 2020, Primus Wind Power released an updated Lithium Ion (LI) control
circuit card designed to improve the AIR turbine funconality with LI
baery types. It is strongly recommended when using LI baeries that the
AIR turbine is also upgraded to this new power electronic circuit card. Pri-
mus Wind Power oers the AIR Loyalty program with discounted pricing
specically for this purpose.
Please contact us at info@primuswindpower.com or 303.242.5820 to
learn more.
(connued)