AIR Owner's Manual
AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc.. AIR Owner’s Manual 3-CMLT-2020-A 47
APPENDIX A (connued)
Lithium Ion Baery Technical Bullen
ADJUSTING REGULATION VOLTAGE
The AIR turbine enters a regulaon mode when the voltage set point is
reached and remains in place unl the baery voltage drops to the “cut-in”
voltage (which is slightly lower than voltage set point). The dierence be-
tween these two (2) values is called “hysteresis” which prevents the tur-
bine from “bouncing” in and out regulaon. The hysteresis is approximate-
ly 0.6V for 12V turbines, 1.2V for 24V turbines, and 2.4V for 48V turbines.
The voltage regulaon set point is adjustable using the potenometer on
the side of the AIR turbine body. To accurately set the regulaon voltage,
disconnect the turbine from the baeries and use an adjustable voltage
source (or power supply, if available) and a mul-meter to apply the de-
sired voltage across the posive and negave turbine leads. With the pow-
er supply o, turn the potenometer screw fully clockwise. Then turn on
the power supply, verify two (2) blinks of the LED on the turbine, and then
turn the potenometer screw counterclockwise very slowly unl the LED
begins blinking. The regulaon set point is now xed to the voltage applied
across the turbine leads. Alternavely, the regulaon set point voltage may
be adjusted using a trial and error method. Use the accompanying chart as
a guide to increase or decrease the voltage regulaon set point using the
potenometer screw on the side of AIR turbine body. Monitor the baery
voltage over a period of me and make only small adjustments unl the
regulaon set point voltage has reached the desired level.
*Adjustment ranges are approximate and actual ranges may vary.
** Turn clockwise to increase voltage and/or counterclockwise to de-
crease voltage.
Please refer to our AIR Owner’s Manual for more informaon or
contact Technical Support at info@primuswindpower.com or
303.242.5820 to learn more.
System
Voltage
Factory
Set
Point
Voltage Regulation
Set-Point
Adjustment Range*
Voltage Change
due to 1/8 Turn of
Potentiometer**
12 Volt 14.1 Volts 13 – 17 Volts 0.5 Volts
24 Volt 28.2 Volts 26 – 34 Volts 1.0 Volts
48 Volt 56.4 Volts 52 – 68 Volts 2.2 Volts