AIR Owner's Manual
AIR 40, AIR Breeze, AIR 30, AIR X MARINE and AIR SILENT-X are trademarks of Primus Wind Power 2013 Primus Wind Power Inc. AIR Owner’s Manual 3-CMLT-2020-A 5
AIR Technical Specicaons
Model AIR 40 and AIR Breeze
Weight 13 lb. / 5.9 kg
Rotor Diameter 46 in / 1.17 m
Start Up Wind Speed 7 mph (3.13 m/s)
Kilowa Hours/month 40 kWh/month @ 12 mph ( 5.5 m/s)
Max. Wind Speed 110 mph (49.2 m/s)
Rated Power 160 was @ 28 mph (12.5 m/s)
Operang Temperature Range: AIR Breeze and AIR 40 are cered under
IEC requirements applying to the temperature range 14° F / (-10° C) to 104º F
(40° C). AIR 40 is CSA. IEC & CE cered. NOTE: The AIR wind turbine is designed
and has proven performance in temperature ranges of -40°C to 50°C.
Model
Weight
Rotor Diameter
Start Up Wind
Kilowa Hours/month
Max. Wind Speed
Rated Power
Cercaons
AIR 30, AIR X Marine and AIR Silent X
13 lb. / 5.9 kg
46 in / 1.17 m
8 mph (3.59 m/s)
30 kWh/month @ 12 mph (5.5 m/s)
110 mph (49.2 m/s)
400 was @ 28 mph / 12.5 m/s
CSA, IEC & CE
AIR 30 wind turbines are eligible to bear the CSA mark with “C” and “US”
indicators. The “C” and “US” indicators signify that the product has been
evaluated to the applicable CSA and ANSI/UL standards for use in Canada
and the US.
Voltage Regulaon Set Point (factory seng)
12 Volt Systems 14.1 Volts
24 Volt Systems 28.2 Volts
48 Volt Systems 56.4 Volts
Regulator Adjustment Range
12 Volt Systems 13 to 17 volts (approximately)
24 Volt Systems 26 to 34 Volts (approximately)
48 Volt Systems 52 to 68 Volts (approximately)
Recommended Fuse Size (AIR 40 and AIR Breeze) *
TOWER LOADS: Shaft Thrust* 80 lb. @ 100 mph wind speed (230 N @ 45 m/s)
* Install overcurrent protection in accordance with CEC and NEC.
12 Volt Systems 20 amp (slow blow)
24 Volt Systems 10 amp (slow blow)
48 Volt Systems 5 amp slow blow)
Recommended Fuse Size (AIR 30, AIR X Marine and AIR Silent-X) *
12 Volt Systems 40 amp (slow blow)
24 Volt Systems 25 amp (slow blow)
48 Volt Systems 20 amp (slow blow)