Primus Wind Power AIR 40 User Manual

AIR Owners Manual 25
Number of
Turbines:
0-30 ft
(0-9 m)
30 ft-60 ft
(9-18 m)
60 ft-90 ft
(18-27 m)
90 ft-150 ft
(27-46 m)
150 ft-190 ft
(46-58 m)
190 ft-250 ft
(58-76 m)
250 ft-310 ft
(76-95 m)
310 ft-390 ft
(95-119 m)
390 ft-500 ft
(119-152 m)
1
8/10 mm
2
6/16 mm
2
4/25 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
00/70 mm
2
000/90 mm
2
000/90 mm
2
2
6/16 mm
2
4/25 mm
2
1/50 mm
2
00/70 mm
2
000/90 mm
2
0000/120 mm
2
*** *** ***
3
4/25 mm
2
2/35 mm
2
0/50 mm
2
000/90 mm
2
0000/120 mm
2
*** *** *** ***
12 Volt Systems, AWG / Metric Wire Size mm
2
*** If your system requires this length of wire, consider using parallel wires.
Number of
Turbines:
0-30 ft
(0-9 m)
30 ft-60 ft
(9-18 m)
60 ft-90 ft
(18-27 m)
90 ft-150 ft
(27-46 m)
150 ft-190 ft
(46-58 m)
190 ft-250 ft
(58-76 m)
250 ft-310 ft
(76-95 m)
310 ft-390 ft
(95-119 m)
390 ft-500 ft
(119-152 m)
1
14/2.5 mm
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
6/16 mm
2
4/90 mm
2
4/90 mm
2
000/90 mm
2
000/90 mm
2
2
12/4 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2
4/25 mm
2
2/35 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
3
10/6 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2
2/35 mm
2
2/35 mm
2
1/50 mm
2
0/50 mm
2
00/70 mm
2
24 Volt Systems, AWG / Metric Wire Size mm
2
48 Volt Systems, AWG / Metric Wire Size mm
2
Number of Turbines: 0-90 ft (0-27 m) 90 -250 ft (27-76 m) 250 -310 ft (76-95 m) 310 -500 ft (95-152 m)
1
14/2.5 mm
2
12/4 mm
2
10/6 mm
2
8/10 mm
2
2
12/4 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2
3
10/6 mm
2
8/10 mm
2
6/16 mm
2
4/25 mm
2