Primus Digital Wind Control Panel Instruction Manual

TROUBLESHOOTING:
1. Wind Turbine is Cycling On/Off: When your battery bank is approaching top off (full charge), you may see
the wind turbine starting and stopping very frequently. This is caused by the wind turbine attempting to do the
final top off on to your battery bank. It may be necessary to lower the voltage set point for the wind generator
regulator to eliminate this problem. See the PWP instruction manual for more information.
2. Wind Turbine Not Operating Properly: Primus Wind Power AIR wind turbines contain a microcontroller
for operating/regulation. From time to time transients or electrical noise (i.e. lightning strikes, keying the SSB
microphone, etc.) may cause these microprocessors to go unstable. To correct the problem turn the WCP D
Stop/Run switch to Stop, wait approximately 5 minutes and then set it back to Run. If this does not resolve the
problem, please refer to the PWP manual for additional troubleshooting advice or contact PWP Tech support.
3. Display Blank: Complete the following steps:
3.1. Check that the DC circuit breaker is in the ON position.
3.2. Confirm that the correct DC voltage is applied to the controller by checking the battery terminals inside
the controller (use a voltmeter) after you have removed it from its enclosure base.
3.3. If the display is still blank after you confirm voltage is applied to the controller and the DC breaker on the
controller has been turned ON then check the fuse.
3.4. Fuse check. Remove power from the controller, unscrew the fuse holder and check the fuse for continuity.
If the fuse has failed the continuity check replace the fuse and repower the controller.
3.5. If the controller display is still blank, controller requires servicing.