User`s manual

18 INSTALLATION AND MAINTENANCE MANUAL 100646_K_PUB_DATE_4_SEP_2009.DOC
1. Washing machine (rear view)
2. Laundry protective earth connection
3. Washing machine external protective
terminal
4. Protective conductor - washing
machine connection
5. Earth mark
Fig.4.4.D.
MULTIPLE MACHINES IN LINE SINGLE PHASE
When multiple single phase machines are connected to the same electrical network, it is necessary to connect
the machines according to fig.4.4.E. The phase of the frequency control and motor which is connected
to the terminal inside the machine, has to be connected alternatively for the first machine with the first phase
L1 of the network, the second machine with the second phase L2, ... The fourth machine must again be connected
to the first phase L1. This assures a better load of the electrical network.
Fig.4.4.E Multiple machines in line