Specifications
26 PROGRAMMING MANUAL 516307 C PUBLICATION DATE 31 JAN 2008.DOC
„I“- INPUTS
The Inputs Menu allows to check the state of the electrical input signals.
INPUT 1
- The technician can verify the input signals of the Easy Control computer one by one.
(See electrical schematic to learn more about each input signal function.)
- Press the „MIDDLE TEMPERATURE“ button to see the nex Input (increased input number).
- Press the „UPPER TEMPERATURE“ button to see the Input state.
oFF = input signal is Low
on = input signal is High
ANALOG INPUT 1
- The value corresponds with the signal measured by the corresponding sensor :
A1 : Air temperature at outlet from Temperature sensor 1.
A2 : Hot air temperature at heating system dryer from Temperature sensor 2.
A3 : Absolute Air Humidity from Humdity sensor.
„L“- COMMUNICATION LINK SUBMENU
By the communication link menu you can set the machine address and the communication line.
FOR MORE INFO : SEE MANUAL PC-NETWORKING COMMUNICATION SOFTWARE
ADDRESS