Specifications
516307 C PUBLICATION DATE 31 JAN 2008.DOC PROGRAMMING MANUAL 27
- Networking : each machine type must have an unique address
- value is selectable between 1 and 255.
- Best is to select for the first machine : 1; second machine : 2; third machine : 3; …
Default: 255
INFRARED
- Selection between infrared communication or RS485 communication networking.
oFF = RS485 communication networking
on = infrared communication
Default: Infrared communication
4.3. INSTALLING NEW SOFTWARE
WHY INSTALLING NEW SOFTWARE
To add new features to the software and to improve the functionality of the dryer, new software releases are
produced by the manufacturer.
INSTRUCTION FOR INSTALLING NEW SOFTWARE
1. Switch off the main power.
2. Open the cover plate of the dryer.
3. The EPROM-Flash memory with the implemented software is the only IC on the logic board that can be
removed.
4. Take the EPROM-Flash memory out of the IC-holder and replace it by a new one. Make sure that you
put the screwdriver between the component and the socket. (see picture)
5. Make sure that you put the new chip at the right position. See fig.3.1.
6. Switch on the main power.
7. The display should be lighting up.
8. If the software is compatible: the new software can be used without reinitialisation.
9. You can clear all the error messages in the system menu to allow a correct determination about the new
software implementation.
10. If the software is not 100% compatible with the previous software version:
The new software will generate a diagnostic message 35. When fault message 35 occurs you must
execute a factory reset in the „S“-submenu (be aware: all your custom made settings will be erased).
(See corresponding paragraph)
For a new dryer computer, after loading the standard program’s, erase diagnostic message 35 finaly by
switching the power off/on.
11. Now you can start a new cycle.