Specifications

30 PROGRAMMING MANUAL 516307 C PUBLICATION DATE 31 JAN 2008.DOC
Press the „UPPER“ Temperature button. On the display :
COIN version:
the coin counter is displayed.
OPL version:
there is no coin counter available.
the temperature and absolute air humidity values are shown in a sequence.
The Coin Counter can be reset :
) Set the key switch in program mode. Press the „UPPER“ Temperature button. On the display :
the counter is displayed (only for a few seconds).
) While the counter is displayed, Press the „UPPER“ Temperature button 3 times.
the counter is now reset to value 0.
5.15. THE PROGRAM CYCLE COUNTER
Set the key switch in program mode.
Press the „MIDDLE“ Temperature button. On the display :
The program cycle counter is displayed.
The Cycle Counter can be reset :
) Set the key switch in program mode. Press the „MIDDLE“ Temperature button. On the display :
the counter is displayed (only for a few seconds).
) While the counter is displayed, Press the „MIDDLE“ Temperature button 3 times.
the counter is now reset to value 0.
Err 41 Service Due is also reset.
5.16. THE LINT FILTER CYCLE COUNTER
Set the key switch in program mode. Press the „BOTTOM“ Temperature button. On the display :
The Lint Filter cycle counter is displayed.
The Lint Filter cycle counter can be reset :
) Open and close the Lint Filter Door.
5.17. SETUP ELECTRONIC COIN SELECTOR
Example :
Program time dryer must be 25 minutes after inserting 3.00 EUR.
Next steps to follow :
- output signal electronic coin selector must be connected to dryer computer input 1 (pin A3)
- attmenu :
setting „cn“ = on
- at „u“ menu :
setting decimal point „dP“ : 00.0
setting „c1t“ = 00.1
- atc“ menu :
setting „dPt“ = 0.00
setting „rt“ = 0.83 minutes