Chapter 1 Installing The SLPA
Figure 5. Power Panel
10. Connect the opposite end of the air hose to the quick connect air fitting on 
the power panel. (Figure 5.)
NOTE: Make certain that all communication port parameters have been 
configured according to purchase order requirements. Print 
parameters must be programmed correctly to achieve the best 
possible print quality. The factory settings are sufficient for most 
applications. Refer to “Configuring The SLPA” on page 73 to 
customize printing setup.
11. Adjust the air pressure to 90 ±10 psi using the air pressure adjustment 
knob and the air pressure gauge (Figure 4): pull up the knob, then rotate it 
clockwise to increase pressure or counterclockwise to decrease pressure. 
Push in the knob when you have set the pressure.
12. If necessary, adjust the voltage (page 33).
13. Plug the AC power cord into the AC power receptacle. (Figure 5.)
14. Plug the SLPA and computer AC power cords into a grounded (three 
prong) electrical outlet of the proper voltage.
15. Set the power switch to | (On) to power on the SLPA.