Applicator Delay Menu
With the SLPA online, press the ↵ key to enter the Applicator Delay menu.
Press ↑ or ↓ to scroll through the submenus: Cycle Delay, Cylinder Extend,
and Vacuum Delay. Press + or – to adjust the values. Press
↵ to set a new
value.
Press the Menu key to place the SLPA back online. SAVING / DELAY TIMES
will display briefly.
Cycle Delay
Sets the length of time the product sensor detects the product until it applies
the label.
Cylinder Extend
Sets the length of elapsed time from the beginning of the cylinder extension to
its retraction.
Dancer Time
Sets the length of time the dance stays down to prevent a failed label tag from