User's Manual

247
A Specifications
Applicator Orientation
The SLPA may be mounted for top, bottom, or side applications.
Product Distance Variation
The relationship between the SLPA and the product is adjustable by moving
the entire machine on the mounting stand. The applicator effective stroke
length is adjustable by setting the cylinder apply pressure along with the
cylinder extend time. The maximum stroke from the bottom of the SLPA is
equal to the length of the cylinder stroke minus 2.50 inches (63.4 mm).
Application Rate
The maximum application rate depends upon the label size and the mode of
operation. The actual applicator cycle time must be totaled with the printing
time, data download, and formatting time (if in Unique mode), to determine
maximum cycle rate for a particular application and label size.
Printing
Print Speed
2.0 inches (50.8 mm) to 10 inches (254 mm) per sec {7204 SLPA}
2.0 inches (50.8 mm) to 8 inches (203 mm) per sec {7304 SLPA}
Slew Speed
2.0 inches (50.8 mm) to 10 inches (254 mm) per sec {7204 SLPA}
2.0 inches (50.8 mm) to 8 inches (203 mm) per sec {7304 SLPA}
Dot Size
0.005 inch (0.127 mm) dots per inch {7204 SLPA}
0.003 inch (0.076 mm) dots per inch {7304 SLPA}
Dot Density
300 dots/inch (11.8 dots/mm) {7304 SLPA}
203 dots/inch (8 dots/mm) {7204 SLPA}