Appendix A Electrical
Electrical
WARNING
The SLPA must be connected to a properly grounded receptacle free of
power surges and fluctuations. Proper operation/protection of the SLPA
can only be guaranteed if its power supply is maintained within the
electrical supply specifications given above.
The power supply cord used with the SLPA must be a 2 conductor plus
ground type with minimum 0.75 mm square conductors. This connector
must incorporate a standard IEC appliance coupler on one end and a
main plug on the other end, which is suitable for use and application of
the product and is approved for use in the country of application.
Pneumatic
Input Voltage
115 VAC
±10%, single phase @ 50 to 60 Hz
230 VAC ±10%, single phase @ 50 to 60 Hz
Power Entry Module One 2.0 Amp, 250 V Slo-Blo fuse
Supply Pressure
Recommended setting for regulated air
supply is 80 to 100 psi (550 to 690 kPa)
Apply Cylinder Pressure
Recommended setting for internal apply
pressure is 40 to 60 psi (140 to 275 kPA)
Air Flow Rates
3 to 5 scfm (85 to 142 sclm)
Connection
1/4 inch NPT
Vacuum
20 inch hg minimum recommended.