User's Manual
IPG/PGL Setup Submenus
149
Auto Uppercase
This parameter enables the printer to print text in all uppercase when using
the ALPHA command.
• Disable. The printer will print text in upper and lowercase.
• Enable. The printer will print text in uppercase only.
The factory default is Disable.
Slash 0
This parameter allows you to print the numeral “0” with or without the slash.
This option applies to all character sets except OCR A and OCR B.
• Disable (the default). Zero is printed without a slash.
• Enable. Zero is printed with a slash.
Select SFCC (PGL)
You can specify which decimal code (1-255) will be used as the Special
Function Control Code (SFCC). The SFCC denotes that the following data is
a PGL command.
The range is 1-255, and the factory default is 126.
Host Form Length (PGL)
Determines how the physical label length (see Label Length under the MEDIA
CONTROL menu) is affected upon receiving an EXECUTE command.
• Enable. The physical label length will change to match the form length
(specified in CREATE command). The physical label size remains at the
new setting until another EXECUTE command is received, or the
PRINTER CONTROL menu settings are changed.
• Var. Length. The physical label length is the longest print element plus
the setting of “Var Form Adjust.”
• Var Dynamic Len. The physical label length will change to the longest
print element defined in CREATE mode plus the setting of “Var Form
Adjust.”
• Disable. Forms printed in EXECUTE mode do not change the physical
label size. Therefore, the size of the form (defined in CREATE mode)
must fit within the current label dimensions, or errors may occur.
NOTE: Changing the form length via the EXECUTE command changes the
LP+ Emulation logical dimensions.
The factory default is Enable.
IGP/PGL SETUP