Chapter 6 Diagnostics for E0xx, Bad NVM, or ILL NVM Errors
Diagnostics for E0xx, Bad NVM, or ILL NVM Errors
If the printer stalls with an LCD message such as ‘E03E DSI CXIWX” or 
“NOVRAM ERR”, reboot the printer and continue. If this situation persists, 
invoke a diagnostic option that will capture the failure dump in a flash file that 
can be later uploaded from PrintNet Enterprise Suite and sent to Printronix 
Customer Support Center (see 
page 273) for further analysis.
This diagnostic option must be enabled for the printer to capture the 
information. To perform this diagnostic do the following the procedure:
1. Enable the ‘Admin User’ option under PRINTER CONTROL. This will 
display the ‘Auto Dump’ option.
2. Enable the ‘Auto Dump’ option under the DIAGNOSTICS menu.
3. When the failure happens, reboot the printer and wait for it to power up 
again.
4. Under the PRINTER CONTROL menu, go to ‘View File List’.
5. Check the file list to see if files ‘autodmp1’ or ‘autodmp2’ are present.
If present, use PrintNet Enterprise Suite to upload these files to your host 
computer.
6. Contact Printronix Customer Support Center and send them the files and 
the printer’s configuration printout. Refer to the PrintNet Enterprise Suite 
User’s Manual for instructions to accomplish these tasks.