Specifications
MEDIA SETUP Submenus
81
Fault Reprint
This option determines how the printer handles data that was printing when 
an error occurred.
• Disable (factory default). The printer will not reprint the label that was 
printing when the error condition occurred.
• Enable. The printer reprints the label that was printing when the error 
condition occurred.
NOTE: When Fault Reprint is set to Enable and a RIBBON OUT condition 
occurs, some labels may not reprint. This depends on the label 
length, print speed selected, and the additional time it takes to detect 
this condition. Be sure to verify that all labels were reprinted after a 
RIBBON OUT condition by using the Ribbon Low indicator as 
described on 
page 81.
Ribbon Low
When enabled, and the ribbon remaining on the supply spindle is less than  
1/8 full, the Attention indicator will flash, and "Ribbon Low" displays on the last 
line of the LCD. A Ribbon Low warning will not prevent printing.
The options are Disable (factory default) and Enable.
The Ribbon Low submenu is available if Admin User is set to Enable in the 
PRINTER SETUP menu.
Units
This item selects either millimeters or inches as the unit of measure.
The options are In Inches (factory default) and In Millimeters.
Set Label Length
This feature selects whether the Sensed Distance value derived from an Auto 
or Manual Calibrate will be used to set the Label Length value in the MEDIA 
SETUP menu.
• Manual (factory default). The Sensed Distance value derived from an 
Auto or Manual Calibrate will not override or change the Label Length 
value.
• Automatic. When an Auto or Manual Calibrate is performed, the Sensed 
Distance value derived from either calibrate will override and change the 
Label Length value. If no Auto or Manual Calibrate is performed, the 
current Label Length value will be used.
NOTE: When Set Label Length = Automatic and Gap/Mark Sensor = Gap, 
the printer will subtract the Gap Length value (in the SENSOR 
SETUP menu) from the Sensed Distance value obtained when the 
Auto or Manual Calibrate was performed.
If you set the label length to Automatic, the Enable setting for Use 
Label Length under the Sensor Setup menu will be ignored.