Specifications
2.42
Applications Manual
© 2003-2005 Prism Media Products Ltd
Revision 1.11Prism Sound dScope Series III
corresponds to a sweep from 0dBFS to –120dBFS.
Specification
Across the amplitude range, the THD+N for line outputs should be less than –60dBr and for
headphone or speaker outputs, less than –57dBr.
4.2.1.10 Signal-to-noise
dScope Configuration:
Signal to Noise Ratio Track 13.dsc
Track Number:
13
Corresponding AP Test File:
2_dnr.at2
.ac3 Test File:
2_200a60.ac3
Duration:
60 sec
Test Signal Description:
200Hz at –60dBFS
Description
This test measures the noise floor of the
EUT
relative to a notional nominal –20
dBFS
signal
amplitude. This is done in the presence of a small signal (200Hz at –60dBFS) so that the EUT cannot
mute its D/A converter.
Method
Play Track 13 and then click the
[OK]
button to start the test.