Specifications
2.47
Applications Manual
© 2003-2005 Prism Media Products Ltd
Revision 1.11Prism Sound dScope Series III
The dScope can measure various types of jitter in a variety of different ways. In this case, the
data jitter
from the EUT's digital output carrier is demodulated and fed to the dScope's analogue
Signal Analyzer. An FFT is calculated to show the spectrum of the jitter, and the peak level of the
jitter is also measured.
Specification
Dolby Laboratories does not provide a precise specification, however a peak jitter limit of 0.25UI (unit
intervals) is suggested in the
IEC60958
standard as a worst-case specification. In general, the figure
should not exceed 0.1UI.
4.2.2.3 Category Code
dScope Configuration:
Cat Code Track 19.dsc
Track Number:
(any)
Corresponding AP Test File:
Chanstat.at2
.ac3 Test File:
(any)
Duration:
Test Signal Description:
Description
This test checks that the Categor
y Code embedded in the
Channel Status
of the
EUT
's digital output
carrier correctly identifies the EUT, as defined in the
IEC60958
standard.