Specifications
2.61
Applications Manual
© 2003-2005 Prism Media Products Ltd
Revision 1.11Prism Sound dScope Series III
Specification
The DVD player should operate within a maximum RMS level of 2.0V
±
10% at any output.
5.2.1.4 Dialog Normalization
dScope Configuration:
Dialog Normalization Track 62.dsc
Track Number:
62
Corresponding AP Test File:
5_dnsweep
Duration:
64 sec
Test Signal Description:
1kHz at 0dBFS
Channels:
L, C, R, Ls, Rs
Description
This test ensures that dialog normalization is turned on and functioning. Dialog normalization allows
the decoder to control the output level of the product based on metadata provided in the bitstream.
Method
Play track 62 and as soon as the track has started, click the
[OK]
button to start the test.
The test track contains a full-scale signal that is stepped down by 1dB every two seconds using Dialog