Specifications

2.73
Applications Manual
© 2003-2005 Prism Media Products Ltd
Revision 1.11Prism Sound dScope Series III
Specification
The distortion should be less than 3% THD+N for all conditions measured.
5.2.1.12 Low Frequency Overload
dScope Configuration:
Low Frequency Overload Track 70-73.dsc
Track Number:
70-73
Corresponding AP Test File:
N/A
Duration:
30 sec (each track)
Test Signal Description:
30Hz; 0dBFS (tracks 70, 71 & 72)
30Hz; -3dBFS (track 73)
Channels:
L, C, R, Ls, Rs
Description
This test ensures correct handling of bass redirection, which involves summation of signals.
Method
Four tracks containing 30Hz sweeps are played in order of descending overload probability. For each
Sweep, the Sub is firstly measured with all other channels set to "small", and then the Left and Right