Store system organization
MODE Store No. 1 2 3 4
A-D Factory Preset Factory Preset Factory Preset Factory Preset
A-D User User User User
D-D Factory Preset Factory Preset Factory Preset Factory Preset
D-D User User User User
For details of the Factory Preset stores, see sections 2.3 and 2.4.
4.5.1. Preview the description and load settings from a store
Before loading a new store it is advisable to preview the store description. This is
accomplished by the following procedure:
Step 1 From the normal Level: display, press either the
<A-D Modes> button or the <D-D Modes> button to
select the desired mode.
Step 2 If you wish to preview a Factory Preset store, press
<Factory Presets> and/or check that the
corresponding LED is lit.
Step 3 Press the selector button for the desired store i.e. one of <1> to <4>. The
corresponding LED will flash.
Step 4 Inspect the text description.
Step 5 Repeat steps 3 & 4 to preview other stores if desired.
You may then cancel the preview by pressing the same store button again [or by
pressing either the [88] or [99] keys, or by double pressing any other store button <1> to
<4> or <Setup Wizard>].
Step 6 To load the store, when in preview mode, press
the [Enter] key. This will set the AD-2 to the
settings contained in the selected store.