Specifications

1.31
Operation Manual
© 2008 Prism Media Products Ltd
Revision 1.05Prism Sound Orpheus
· Mic/line input combos 1-4: XLR for microphones, with 10dB to 65dB finely-adjustable gain and
switchable phantom power; TRS jack for line inputs, with switchable +4dBu/-10dBV level, can
operate in balanced or unbalanced mode. See Analogue inputs.
5.4.1 Fuses and ratings
TO PREVENT SHOCK HAZARD, THE ORPHEUS HARDWARE SHOULD ONLY BE
OPENED BY QUALIFIED PERSONNEL. REMOVE THE POWER LEAD FROM THE
UNIT BEFORE REMOVING THE TOP COVER.
Fuse locations and ratings are as follows:
FUNCTION
LOCATION
TYPE
Mains
Rear panel
500mA(T), 20mm, glass
Note that no fuses or any other user-serviceable parts or options are located inside the
Orpheus unit.
5.5 Stand-alone operation
It is possible to operate Orpheus without a FireWire connection to a host computer. This is done by
setting up the unit as required using the Orpheus Control Panel applet whilst it is connected to a host
computer via its FireWire interface, then placing the unit in standby by pressing the standby button,
before disconnecting the unit from the host and power source. When the unit is re-powered, and
detects that no FireWire connection is active, it reloads the settings which were previously stored.
Since all of the outputs have optional mixers within the Orpheus hardware whose inputs include all of
Orpheus' input connectors, it is possible, for example, to connect the digital input pair to one or more
analogue output pairs, and to mix one or more analogue input pairs to the digital output pair. The
synchronization source and sample rate can be set in the usual way. Thus stand-alone mode can be
used to configure a stand-alone D/A converter and A/D converter, with static mixing if required.
ADAT Direct mode
ADAT Direct mode allows Orpheus to operate as an eight channel analogue-to-ADAT and
ADAT-to-analogue converter. ADAT Direct mode is activated by setting the ADAT control in the Unit
Settings panel to 'Direct'.
In ADAT Direct mode it is possible to control Orpheus using the Control Panel applet in the usual way
while Orpheus is connected to a host computer via FireWire. If Orpheus is not connected to a host
computer, ADAT Direct mode can still be used as a stand-alone mode, by saving pre-selected
settings using the standby button as described above.
Signal routing in ADAT Direct mode
The eight ADAT output (send) channels are fed directly from the eight analogue input channels. Any
signals sent from the host computer over FireWire (if connected) destined for the ADAT outputs are
ignored by Orpheus.
The eight channels sent from the host computer over FireWire (if connected) destined for the
Orpheus analogue outputs are ignored by Orpheus, and replaced by the eight ADAT input (return)
channels. This means that the analogue output DAW/Mix switch can still be used: in the DAW