6. SINGLE PAGE
The SINGLE page (F2) shows the Prisma DI-5C readings in sequential cylinder order.
For Crankshaft deection measurement the Header is Cyl 1, Cyl 2, Cyl 3 etc. (cylinder).
If the Vee engine box on the Main page is checked, “Cyl” will be exchanged to Web.
If the document is a cylinder liner Ovality measurement the Header will state Lev 1,
Lev 2 etc, (level). The top left picture illustrates the meaning of positive and negative
deection.
Max Deection is displayed for each cylinder at the bottom of the column. The deec-
tion Limit Value can be changed to match the specied tolerances. The limit is saved
together with the document. If the deection remains within the pre-set limit the eld
will be Green. If the limit is exceeded, the eld will indicate Red, as seen in screenshot
above.
Use the red arrows to scroll through cylinders/levels. For crankshaft measurement the
maximum number of cylinders is 24. To check a dierent document, click the ´Load´
button and to remove all data, click ´Clear´.
NOTE! If a new document is loaded, the previous document will be cleared.
To printout the page, go to “File – Print Document”, check the requested page(s) and
press OK.