www.prismatibro.se
8. DIAGRAM PAGE
The DIAGRAM page (F4) produces a +/- deection curve for each position of the crank/
cylinders, e. g. all position “A” crank readings for each cylinder, maximum 24 cylinders
per document in a crankshaft measurement.
If it is an Ovality measurement, 1 document per cylinder is used and the A-E positions
describe the readings obtained when rotating the instrument to the desired position.
The X-axle show the levels.
The maximum deection is graphically illustrated, showing the variances between the
highest and lowest readings of each cylinder.
This graph is also an extension of the previous Comparison Page where an older
document reading can be displayed together with the new document data.
The diagram height (scale) can be adjusted by clicking the adjustment arrows.
The height adjustment aects both “+” and “-“ simultaneously.
Print, Load and Clear documents at will, as previously described.