ese instructions are only applicable when installing a CFM600 fan in a 30" wide chimney style hood.
e Prizer 30" wide chimney style hood has an adapter plate installed inside the hood. In order to install a CFM600 fan within
a 30" wide chimney style hood, rst remove this adapter plate, and use this plate in lieu of the plate shipped with the CFM600 fan.
Remove the adapter plate from the 30" wide chimney style hood by removing the four (4) 10-24 nuts. (see Figure 12.)
Unpack the CFM600 fan (shipped separately).
Remove the CFM600 fan from the mounting plate, by removing the four (4) screws holding the fan to the plate.
Attach the CFM600 fan to the adapter plate previously removed from the 30" wide chimney style hood.
Insert the CFM600 fan unit into the 30" wide chimney style hood using the previously removed four (4) 10-24 nuts.
Separate Fan from
CFM600 Mounting Plate by
removing (4) Mounting Screws.
Discard Mounting Plate.
Remove Adapter Plate by
removing (4) 10-24 Nuts.
Attach the 600CFM fan to
the Adapter Plate (see below).
Reinstall fan assembled unit.
Attach Fan to the 30" wide
Chimney Hood Adapter Plate
(installed within 30" Chimney Hood).
Use previously removed
(4) Mounting screws.
Insert the Fan assembled unit
into 30" Chimney Hood.
Plug Fan Connector
into mating Connector in Hood.
Adapter Plate removed
from 30" Chimney Hood.