Installation instructions

1. Install three wires: black, white and green (#16 AWG) in 1/2" conduit from the service panel to the hood junction box.
Power supply must be rated for 120v, 60Hz, 15 amps (minimum).
Remove junction box and selected knockout. en install the strain-relief (conduit) connector in the removable
back panel. For PMLSS-28” & 34” run power line through single knockout at top and route to junction box
mounted on back.
Remove the junction box from the removable back panel. Connect black wire to power-supply black wire, white wire
to power-supply white wire, and green wire to power-supply green wire.
Place all wiring connectors inside junction box and re-install on removable back panel.
2.
3.
4.
2-1/2"
2-1/2"
2"
Knock Out Holes Location
MLSS - 40” to 70” wide
PMLSS - 40” to 70” wide
3"
Knock Out Location
CMLSS
Knock Out Holes Location
10"
3-3/4"
2 "
Knock Out Holes Location
MLSS - 28” to 34” wide
PMLSS - 28” to 34” wide
3"
2-1/2"
2-1/2"
2"
3"
Knock Out Holes Location
MLFS
2-1/2"
2-1/2"
2"
ELECTRICAL CONNECTIONS
7
Figure 6-A.
Figure 6-C.
Figure 6-D.
Figure 6-B.