Professional Water Filtration Systems www.proaquawater.com.
TABLE OF CONTENT SECTION PAGE INSPECTION & PREPARATION INSTALLATION DIAGRAM VALVE SETUP ....................................... 2 - 4 .................................................... 5 ................................................................. 6 - 7 SYSTEM INSTALLATION .................................................... 8 - 10 VALVE PROGRAMING .................................................... 11 - 12 ADVANCE SETTINGS .............................................................
INSPECTION & PREPARATION IMPORTANT! Before installing - Please read the entire manual and become familiar with instructions and parts needed before proceeding with the installation. ! System Inspection Please take the system and all the components out of the box. Inspect the system and all the connection fittings carefully, make sure nothing was damaged during shipping. If any part is cracked or broken, please do not proceed with the installation and contact Pro+Aqua or your distributor for support.
INSPECTION & PREPARATION CONT. Required Tool List for System Installation • Channel Locks • Adjustable Wrenches • Screwdriver • Teflon Tape • Razor Knife ! IMPORTANT! Additional tools may be required if modification to home plumbing is required. II. System Operation Parameter and Installation checklist ! IMPORTANT! The following condition for feed water supply must be met or warranty will be void and manufacturer assumes no responsibility for damage to system or property. 1.
INSPECTION & PREPARATION CONT. III. Installation Safety Guide • Handle with care when moving the water filtration system. Do not turn upside down, drop, drag, or set on areas with sharp protrusions. • The system works on standard 120v power plug only. Do not use any other transformer except the one that is included with the system • Transformer must be plugged into an indoor 120 volt, grounded outlet only. • All of tanks have level adjusting tank bases.
-5- Well Water Source Well Water Pressure Tank Galvanized / Brass Pipe Ground Jumper Wire City Water Source Ball Valves PRO-WELL System Drian Line Optional Whole House Water Softener Optional Sub-Micron Post Filter Optional UV Filter Galvanized / Brass Pipe Ball Valve To Home INSTALLATION DIAGRAM Optional Water Bypass
VALVE SETUP ! IMPORTANT! Locate and test the main water supply valve to the home before installing the system. If the main water supply valve fails to shut off the water completely during the test, we recommend contacting a licensed plumber to fix the valve before starting the installation. WARNING! If the system is installed on a metal (Conductive) plumbing system, i.e.. copper or galvanized metal, the plastic components of the system will interrupt the continuity of the plumbing system.
VALVE SETUP CONT. 1. Lubricate the o-rings on the Adapter Couplings to avoid any leaks. 2. Attache the bypass valve onto the control head by pressing it onto the Adapter Couplings. 3. Secure the Bypass to the valve using the Screws and Metal Clips. 3 Valve Preparation 1. Remove the tank from carton 2. Lubricate both O-rings on the bottom of the control valve (center and outer).
SYSTEM INSTALLATION 3. Lubricate the riser tube located on the opening of the tank. 4. Install the upper basket on the bottom of the valve by lining up the tabs, pressing in, then turning the basket counterclockwise to lock it in place. 5. Place the upper basket over the distributor tube and push the valve down to the tank and thread the valve on the tank by turning it clockwise. Be sure not to cross-thread the valve on the tank. The valve should thread easily in the tank.
SYSTEM INSTALLATION CONT. ! IMPORTANT! On copper plumbing systems be sure to install a grounding wire between the inlet and outlet piping to maintain grounding (see diagram on pg. 5). WARNING! DO NOT SOLDER WHILE SYSTEM IS CONNECTED. Any solder joints being soldered near the valve must be done before connecting any piping to the valve. Failure to do this could cause unrepairable damage to the valve.
SYSTEM INSTALLATION CONT. 4. Locate the included drain hose. Using a sharpies, mark 1/2” from the end of the drain hose. Connect the marked end of the drain hose into the Quick Connect drain port on the valve until it reaches or passes the 1/2” mark (Remove Locking Clip before pushing hose in). Run the drain hose to the nearest laundry tub or drain. This can be ran up overhead or down along the floor. Drain hose should be a minimum of 1/2”.
VALVE PROGRAMING 5 System Startup 1 4 2 1. Time of Day 2. Status 3 3. Time Remaining 4. Backwash Mode Timer The back-light on the screen will go off automatically after one minute if no buttons are pressed. To light it up again press any button on the touch pad. Setting Button 1. Enter into setting menu 2. Confirm the current setting, and enter into the next step 3. When used simultaneously with up button, it will enter into master programming Up / Down Buttons 1. Adjust current settings 2.
VALVE PROGRAMING CONT. 4. When the backwash cycle is complete, the valve will advance to the brine draw (BD) position then to the (RR) position. The display will show the (Rapid Rinse) cycle, allow the water to run for the entire rinse cycle 5. When the Rinse Cycle is complete, the valve will advance to the “BF” then the “SR” position. 6. When the cycles complete, the valve will automatically advance to the SERVICE position.
CONGRATULATIONS! Your system is ready for use. Please document the system installation date and maintain the system at its recommended interval. ? ADVANCE SETTINGS: The following settings have been pre-set from the factory and are only meant for special application that requires customized settings. Continue only if you require customization of the following settings.
ADVANCED SETTINGS 1. Setting the Valve Mode Default setting is "Timer" NOTE: Meter and Meter Delay options are not used, there is no need to set them. Flashing Use the step below to set the Valve to Timer mode. Set To Timer Mode (T) Timer (Default Setting) This mode counts down. Flashing Press Up or Down buttons to change mode Press the Settings Button to accept and continue. Meter (Not Used) (Regenerate Immediately) This setting is not used.
ADVANCE SETTINGS CONT. 2. Backwash Time and Hours Override (Change only if needed) Flashing Timer Mode Default: 2:00 AM every 072 hours.
ADVANCE SETTINGS CONT. 3. Setting the Back Wash Time Flashing Set the Time Default setting is 015 Flashing Press UP or DOWN buttons to change Back Wash time (Minutes) Range: 0 - 999 Press the Settings button to accept and continue to next digit Flashing Press the Settings button to accept and continue.
ADVANCE SETTINGS CONT. 4. Setting the Brine Time (SKIP - This setting us not used) Press the UP button to change to SET-7 Flashing Press the Settings button to accept and continue. Flashing 5. Setting the Rapid Rinse Time Default setting is 010 Minutes Press UP or DOWN buttons to change the Rapid Rinse time Range: 0 - 999 Flashing Press the Settings button to accept and continue to next digit Flashing Press the CYCLE button to accept and complete the setup.
FEATURE & DISPLAYS 1. Memory During Power Failure All program settings are stored in permanent memory. Current valve position, cycle step elapsed, time of day are stored during the power failure. Reset the current time is necessity when power up. If the valve stopped at a backwash stage when power failure, the valve will return to prior position when it powers up. It takes 4 to 5 minutes to reset to the position.
FEATURE & DISPLAYS CONT. 4. Manual Immediate Backwash Immediate Backwash When the valve is in service position, press and hold the be initiated. button for 5-6 seconds, an immediate backwash will Examples: "BW" Flashing (ready to "Backwash"). The piston is moving to position. The piston is in “BW” position and the timer starts to count down. Press the button to force skip to next cycle. "BD" Flashes, moving piston to “BD” position then skips to “RR” position.
PRODUCT DIMENSION Model PRO-WELL-1E Tank Size 9”x48” A Pro+Aqua Well Series A 55” B C - 20 - B 48” C 9.
SYSTEM TROUBLESHOOT Problem Cause Correction 1) The control fails to Backwash automatically A) Transformer damaged A) Replace the transformer B) Electronic controller or sensor damaged B) Replace or repair 2) Backwash at wrong time A) Timer improperly set, due to power failure A) Reset timer 3) loss of capacity A) Rinse fouling A) Consolidate the rinse tank, clean the rinse and prevent future fouling B) Poor distribution, channeling (Uneven bed service) B) Check distributors and backwash flow
INSTALLATION NOTES - 22 -
MAINTENANCE LOG - 23 -
MAINTENANCE LOG - 24 -
LIMITED PRODUCT WARRANTY PRO+AQUA warrants that your new Well Water Filtration System is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble free service. Five Year Valve, Electronics and Tank Guarantee PRO+AQUA will replace any part on the valve or electronics which fails or the media within (5) five years from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship.
Professional Water Filtration Systems www.proaquawater.com.com © Copyright PRO+AQUA. All Rights Reserved.