Professional Water Filtration Systems www.proaquawater.com.
PRO+AQUA filtration systems are designed in California USA and are made from quality NSF Approved filters and components. System Inspection Before Starting Remove the system and all the components out of the box, take note of all parts. Inspect the system housings, fittings and connections carefully, make sure nothing was damaged during transit. If any part is cracked or damaged, please do not proceed with the installation and contact us or your distributor for an exchange or diagnosis.
-2- Well Water Source Well Water Pressure Tank Galvanized / Brass Pipe Ground Jumper Wire City Water Source Stage 1 Housing Ball Valves PRO-100-E System Stage 3 Housing Optional Water Softener Optional Water Bypass Optional Sub-Micron Post Filter To Home Installation Diagram Optional UV Filter Galvanized / Brass Pipe Ball Valve
System installation 1 2 MAIN WATER SUPPLY VALVE Shut off the main water line to your home. Install system to wall using the included SS bolts. 3 4 PR BUTTON IN OUT Attach your incoming supply line to the “IN” Port on the system then attach the line going into your home to the “OUT” port on the system. Plastic fittings recommended. DO NOT solder. 5 Unwrap cartridges and drop into the correct housings, centering on the stand pipe in the bottom of the housing.
Flow Reversal Depending on the location of your feed water and the entry location of the pipe to your home, you may need to flip the direction flow of your system. This will reverse the flow of your system to be Left to Right. 1 2 Gauges PR BUTTON IN OUT IN OUT Carefully remove the Pressure Gauges from the system. Remove the 12 bolts and washer to separate the Cap Module from the Bracket. 3 4 IN OUT OUT - FLIP - IN OUT Flip the Cap Module so the IN port is on the opposite side.
Replacing Your Filters Replacement Filter Set: FC-PK-100E To insure your system keeps performing at its best, only use original OEM Certified filters, untested filters will reduce performance and void its warranty. Before starting: Turn incoming water off then press and hold the PR button to relief the pressure in the system. Ensure to place a bucket or rag to catch any splashing water.
? Optional Add Ons: Ball Valves, Bypass, Ground Jumper Wire, Water Softener, Post Filter, and UV Filter are not included. ! Warning: The plastic components of the system will interrupt the continuity of the grounded (conductive) plumbing system. A grounded “jumper wire” bridging the equipment to the plumbing system must be installed prior to systems use. Consulting a Licensed Plumber is highly recommended (see Installation Diagram).
Professional Water Filtration Systems www.proaquawater.com.com © Copyright PRO+AQUA. All Rights Reserved.