Hardware manual

LT-4201TM/4301TM Hardware Manual
31
Environmental Characteristics
Enclosure Requirements
LT system components are designed as Zone B, Class A industrial equipment
according to IEC/CISPR Publication 11. If they are used in environments other than
those described in the standard, or in environments that do not meet the
specifications in this manual, the ability to meet electromagnetic compatibility
requirements in the presence of conducted and/or radiated interference may be
reduced.
All LT system components meet Euro
pean C
ommunity (CE) requirements for open
equipment as defined by EN61131-2. You must install them in an enclosure
designed for the specific environmental conditions and to minimize the possibility of
unintended contact with hazardous voltages. Use a metal enclosure to improve the
electromagnetic immunity of your LT system. Use enclosures with a keyed locking
mechanism to minimize accidents.
Environmental Characteristics
LT meets CE requirements as indicated in the table below, and is intended for use
in a Pollution Degree 2 industrial environment.
The table below gives the general environmental characteristics:
Characteristic Specification
Standard
compliance
IEC61131-2
Ambient operating
temper
ature for the
display
module and
the rear module
Horizontal installation 0...50°C (32...1
22°F)
Vertical installation 0...40°C (32...104°F)
Storage temperature - 20...
60°C (- 4...140°F)
Stora
ge altitude 0...10,000 m (0...32,808 ft)
Operating altitude 0...2,000 m (0...6,560 ft)
Surrounding Air and Strage Humidity 5...85% w/o condensation (non-condensing,
wet bulb temperature 39°C (102.2°
F) or
less)
Degree of pollution IEC60664 2
Degree of
protection
IEC61131-2 IP20 with protective cover
s in place
Corrosive gases Free of corrosive gases
Dust
0.1 mg/m
3
(10
-7
oz/ft
3
) (non-conductive
levels)
Atmospheric pressure (Operating Altitude) 800...1,114 hPa (2000 m (6,561 ft) or lower)
Vibration
resistan
ce
Mounted on a DIN rail 3.5 mm (0.138 in.) fixed amplitude from
5...8.4 Hz
9.8 m/s
2
(1 g
n
) fixed acceleration from
8.4...150 Hz
Mounted on a panel 3.5 mm (0.138 in.) fixed amplitude from
5...8.6 Hz
9.8 m/s
2
(1 g
n
) fixed acceleration from
8.6...150 Hz