All-in-One unit for Control, Operation Which means... and Display Graphical display and Touch Operation! Pro-face's combined HMI and control software is easy to use. Less wiring and less space! Frees up space around the control panel ! NEW Simple wiring means easier maintenance too.
Our complete lineup matches your needs 5.7 inch Functional Specifications 64Colors STN LCD Item Sink Sink output Sink output output ADP 16 16 16 16 16 16 16 16 Analog Input (ch) *1 2 2 2 Analog Output (ch) *1 1 2 2 High-speed Counter *1 4*2 4*2 4*2 Pulse Output *1 4*3 4*3 4*3 Thermocouple(J/K) Temperature Input Blue / White CFL (lifespan: more than 25,000 hours when continuously lit) Electrical Remote I/O (Flex Network) *1 Compatible with Flex Network units.
Reduces wiring and expands system scalability Integrates easily into compact equipment 5.7 inch 5.7 inch 16 input points and 16 output points make for easy integration into your current system 5.7 inch Built-in DIO (Sink output) Type Tool Connector Use Flex Network to connect up to 1008 points (63 nodes) over a maximum of 400m (with 6Mbps, 200m x 2 ch). 5.
Comes equipped with analog I/O, temperature input and pulse output 5.7 inch 5.7 inch 5.7 inch Easily... • Control pressure and flow • Set positioning • Monitor temperature, etc. ADP only * 5.7 inch : Sink Type Built-in 32-point DIO + 2-point AD/1-point DA Built-in 32-point DIO + 2-point AD/2-point DA +3-point Thermocouple Input Built-in 32-point DIO + 2-point AD/2-point DA +2-point Pt100 Input : Source Type * Built-To-Order product. Please contact your local Pro-face distributor.
Input This I/F unit's high-speed remote I/O (6Mbps/12Mbps) is so fast, you won't think you are using a remote connection. Up to 1008 I/O points can be connected, with a communication delay of only 0.94ms (for 512 points at 12Mbps). The network can be extended up to 400 meters (2 channels at 6Mbps). Output Type A1/A2 Rated Voltage Max. Allowable Voltage Input Type Rated Current Input Resistance Standard Operating Range Type B+ Type A1/A2 Rated Voltage Rated Voltage Range DC24V DC26.
Input Derating *1 Operation Range ON Voltage: DC19V or more OFF Voltage: DC5V or less Input Delay Time Common Lines Common Line Allocation Input Points OFF to ON: 0.5 to 20ms or less*2 ON to OFF: 0.
Pt100 Input Item Specifications Item Specifications Subjected Resistance Temperature Sensor Pt100 Subjected Resistance Temperature Sensor Thermocouple (J/K Type) Measurable Temperature Range Accuracy No. of Input Channels Temp. Conversion Data*1 External Wiring Length Conversion Time Insulation Celsius: -50°C to +400°C Fahrenheit: -58 F to +752 F ±1.0% (Full Scale) Fahrenheit: -580 to +7520 Each Channel: 50m max. Approx.
Easy Screen Creation Screen Editor and Logic Program Development Software Easy Logic Programming Supports Ladder Monitor Provides control in emergency situations, when you want to see equipment programs on location. Allows LT ladder monitoring on the touch panel without disrupting control or PLC communication and scrolls easily through monitor screens. Variable monitoring (device) and decimal or hexadecimal display are also possible. Data previously created with LT Editor can also be used.
Retention Coil M Negated Coil NEG N Shift Left SHL M IM Unlatch Coil RST R Unlatch Retention Coil RM RM Latch Coil SET S Latch Retention Coil SM SM Logical Add Shift Instructions NM A C OR XOR Add C Subtract C RCR Multiply MOV MOV EN DN IN OUT Mathematical Instructions D B C Transfer SAL SUM A SAR Less Than or Equal To (<=) LE LE EN Q A A C SAR EN DN A Divide NE On Delay Timer PID TON ADD ADD EN DN A C SUB SUB EN DN A C MUL MUL EN DN A C DIV
16-point Sink/Source Input, 16-point Sink Transistor Output 32-point Sink/Source Input 16-point Sink/Source Input, 16-point Transistor Source Output 32-point Sink/Source Input, 32-point Transistor Sink Output 4-channel Analog Input Unit DIO Terminals Model Analog Units FN-X32TS41 FN-XY16SK41 Allowable Voltage Range DC20.4V to DC28.8V Allowable Voltage Drop 10ms or less (for DC24V power supply) 3.
FN-X16TS41 Single-axis Positioning Unit Electrical Rated Voltage Rated Voltage Range Allowable Voltage Drop Power Consumption In-rush Current Voltage Endurance FN-HC10SK41 DC24V DC20.4V to DC28.8V 10ms or less (for DC24V power supply) 2.5W or less 15A or less AC500V 20mA for 1 min. (between I/O and earth terminals) DC500V at 10MΩ or higher (between I/O and earth terminals) 0˚C to 55˚C –25˚C to +70˚C 30% RH to 95% RH (non-condensing) Level RH-1 30% RH to 95% RH (non-condensing) Level RH-1 0.
FN-X32TS41 FN-XY16SK41 (Sink/Source Input Type) FN-PC10SK41 FN-XY16SC41 (Sink/Source Input & Sink Output Type) FN-HC10SK41 (Single-axis Positioning Unit) (Sink/Source Input & Source Output Type) (High-speed Counter Unit) Z Phase (with Open Collector) FN-HC Unit Single-axis Positioning Unit OV DC24V *4 24V L Input 0 *5 Input 0 *6 Internal circuit Input 15 Input 0 *7 Internal circuit Internal circuit Input 15 Output 0 Input 15 Output 0 Output 15 OUT1 L OUT2 O-COM A+ Pulse Output
Smooth system integration of Pro-face products is assured with a total support network. W D EE SS U U PP PPOORRT T WOO RR LL D DW W ID Coventry, ENGLAND Hoofddorp, THE NETHERLANDS Malm , SWEDEN Malmö, Copenhagen, DENMARK Seoul, SOUTH KOREA Paris, FRANCE Solingen, GERMANY Dielsdorf, Switzerland Osaka, JAPAN Saline, Michigan Shanghai, P. R.