Specifications

© Audio Trade GmbH · Pro-Ject Debut III/Phono SB / Ortofon OM 5E · Revision 1.3.08/1.5.08
5
Switching on and off
Pressing the power switch (20) alternately starts or stops the motor.
Changing replay speed
Press the speed change button (24) to switch between 33 and 45 r.p.m.. The selected speed is shown
respectively by the lit green LED (33 r.p.m.) or red LED (45 or 78 r.p.m.).
To replay records at 78 r.p.m. perform the following steps: Remove the platter (5) and using the tool (3a)
from the accessory kit. Fit the belt (3) around the larger diameter step of the pulley (2). Replace the Platter,
start the turntable at 33 r.p.m. and switch the speed to 45 r.p.m., the platter will then revolve at 78 r.p.m..
To play at 45 or 78 r.p.m. please always start the turntable at 33 r.p.m. and then switch to the higher speed
when it has attained full speed.
Maintenance and cleaning
Your record player requires little or no regular maintenance. Remove dust with a slightly moistened antistatic
cloth. Never use a dry cloth because this will create static electricity which attract more dust! Antistatic
cleaning fluids are available at specialist stores but must be applied sparingly to avoid damage to rubber
parts. It is recommended to fit the needle cover before cleaning or maintenance is carried out to avoid damage.
If the player is not used over a long period of time the drive belt can be removed to prevent unequal stretching.
!
Always disconnect the record player from the mains power supply as a precaution before maintenance!
Useful tips
The record player should be positioned on a low-resonance surface such as wood or multiple layer ply board
to avoid structural vibrations disturbing replay.
Fitting and connecting the cartridge
** All cartridges with half inch mounting holes can be fitted. Leaving the needle's protection cover on, fit the
cartridge to the headshell using the screws supplied with the cartridge by passing one screw through each
slot in the headshell (21). Do not tighten the nuts yet.
Connect the tonearm wires to the cartridge pins as follows:
white left channel positive (L+)
red right channel pos. (R+)
green right channel return (R -)
blue left channel return (L -)
The full sound quality of the record player can only be achieved if the cartridge is correctly adjusted. Particular
tools like the PRO-JECT alignment tool are required to accomplish this job properly.
If you are not well acquainted with the adjustment of cartridges you are advised to call upon the willing help of
your PRO-JECT dealer to accomplish this task for you.
Adjusting the azimuth
** The cartridge needle must be vertical in the record groove in order to trace
the groove wall modulations correctly.
A small screw at the bearing end of the arm allows incorrect azimuth to be
corrected if your needle is not mounted exactly perpendicular to the cartridge
body (which is often the case).
Slacken off the screw just enough to be able to revolve the arm tube without
applying force. Note! Do not remove the screw completely!
Screw
With the aid of a good magnifying glass adjust the needle until it is vertical in the groove (i.e. perpendicular
to the record's surface). Ideally this should correspond to the top surface of the cartridge body being parallel
to the record surface. When you are satisfied that the needle is vertical retighten the screw carefully.
Under no circumstances should the arm tube be adjusted with the needle still in the record groove!
Irreparable damage may be caused to the cantilever suspension! The arm must be lifted to make
each adjustment and lowered afterwards to check it.