Owner`s manual

GENERAL SPECIFICATIONS
AC Receptacle: 2 – Dual Three-prong
Battery Polarity Protect: Yes (Fuse)
DC Fuse (Recommended): 70 A
Dimension (L x W x H): 13 x 6.25 x 3.75
Efficiency: 88%
Output Short Protect: Yes (Button Breaker)
Output Waveform: Pure Sine Wave (<3% Thd)
Operating Temperature Range: 32° F – 158° F (0° Fc – 40° C)
Overload Protect: Yes
Storage Temperature Range: -22° F - 158° F (-30° C – 70° C)
Part Number: 79400 With Outlets
Part Number: 79405 Hardwired
Thermal Protect: 50 +/-5 Deg C
Weight: 13 Lbs
ELECTRICAL SPECIFICATIONS
Battery Low Shutdown: 10.5 VDC
Continue Output Power: 400 W
Input Voltage Range: 10.5 – 15.3 VDC
Input Full Load Current: 40 A
No Load Power Draw 0.5 A
Output Frequency: 60 +/- 0.05 Hz
Output Power: 400 Watts
Output Voltage (At No Load): 120 Vac Rms +/- 3 V
Output Voltage (At Full Load): 120 Vac Rms +/- 5 V
Peak Output Power: 1000 Va Surge For 5 Seconds
CAUTION: ALWAYS PLACE THE INVERTER IN AN ENVIRONMENT WHICH IS:
(A) WELL VENTILATED
(B) NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE
(C) OUT OF REACH FROM CHILDREN
(D) AWAY FROM WATER / MOISTURE, OIL OR GREASE
(E) AWAY FROM ANY FLAMMABLE SUBSTANCE
4
TRUEPOWER400PS FEATURES
1. ON / Off Switch turns the inverter to ON or to OFF.
2. Shore Power light illuminates when you are connected to shorepower. (shorepower
refers to the AC input power from a utility grid, generator or external AC source)
3. Inverter / Fault Light illuminates Green when the inverter is operating and
illuminates Red for fault conditions such as over temperature, output overload,
or battery over voltage.
4. Two AC Outputs to power connected appliances.
5. Supplemental Circuit Protection Button may trip if there is an over-current (over
10 amps) or a short circuit.
6. GFCI opening enables the Reset and Test monthly capabilities.
7. Fan (internal) activates when the internal temperature of the inverter increases.
The fan speed varies with the internal temperature and turns off when the inverter
cools down.
1. DC Input Cables
2. AC Receptacles
3. AC Input cord for shorepower
4. Wiring box access panel (Top panel)
5. AC Strain Relief for hardwiring
6. Chassis ground lug
7. Remote control jack
8. Mounting flanges (Side panel)
9. Ventilation openings provides
air circulation (Side panel)
TruePower400PS FeaturesSpecifications
15
Figure 2
9
8
4
6
7
1
2
3
5
Remote
DC Grounding
Connector
AC Output
AC Input
DC Input
Figure 1
6
7
5
4
3
2
1
RESET
RESET
TEST
TEST
Shore ON
Red: Inverter Fault
Green: Inverter ON
POWER STATUS
POWER
AC SHORE
BREAKER