Operating instructions

18.Spare parts list -20-
Wear, tear and replacement part requirements depend on specific operating conditions. The recommended quantities
are based on experience and are not binding.
Converter CG
®
...
(C) Consumable parts
(R) Recommended spares
(S) Spare parts
Recommend
in operation
[years]
quantity
Part No. Description C/R/S 1 2 3
95 A 9003 Catalyst cartridge CG2-C C b.d.* b.d.* b.d.*
95 A 9070 O-ring set for converter CG2 R/C b.d* b.d* b.d*
95 A 9057a Heater CG-2; 115/230V, 50/60Hz S * * *
PM6C1EC-ALAJAAA PID **Specify programming for CG-10 S * * *
601-0097 SSR S * * *
KMTSS032U
834-1330
Limit Thermocouple
Alarm Relay (GP, DPDT, 120 V coil)
S
S
*
*
*
*
*
*
b.d.* = by demand. O-rings are typically replaced with cartridge change. Further replacement should not be necessary.
* = Preventative replacement not necessary. Replace if defective
20.Appendix
Wiring diagram GC-10
PID Temperature control settings and operation
M&C Produc
ts Analysis Technology 9-2.0-MEUS