GENSD7D 7,000 Surge Watts/5,500 Running Watts Diesel Generator 18
CONTROL PANEL
AC Voltage
POWER units in KW (kilowatts)
Multi-function Display, relates to:
Left, Right, Up, Down, Enter (Function)
1) Frequency (Hz) 6) Generator temp. ()
Engine Oil Warning
2) Current (Amps) 7) Blank (Turns Red when Oil Pressure is low)
3) Battery voltage (V) 8) Auto protection indicator This Digital Control Panel will display Voltage,
4) Run time (Hours) 9) Diesel valve on indicator Hz and Kw. (All other features are non-functioning.)
5) Engine temp. () 10) Starter indicator
When you start the generator, the Control Panel will display all “000”.
When you turn the Breaker to the “On” postion, Volt (1), Kw (2), and Hz (3) will appear.
If you need to adjust the Voltage (1), lightly tap the FUNCTION button (6), and the Volt display will begin to flash. Press Right Arrow (6A) to increase
and Left Arrow (6A) to decrease.
(If the toggle switch is set in the 120V position, the Volt display will show “120”. Generally, you will not need to adjust this setting. If the toggle switch
is set in the 240V position, the Volt display will show “240”. In this situation, you may need to increase the voltage to 243 or 244)
When you turn the Breaker to “On” position, Power (2) will display the Kw being generated. This is not adjustable.
When you turn the Breaker to “On” position, Hz is displayed. This is not adjustable.
When you turn the Breaker to “On” position, Battery Voltage is displayed when you are charging a battery. This is not adjustable.
Automatic Voltage Protection
The voltage digits will flash if exceeding the set values ±10%. The protection will start after 7 seconds under voltage or 3 seconds over voltage.
After the protection is enabled, the digits will keep flashing and show current protection value.
Automatic Frequency Protection
50 Hz47~55
60 Hz57~65
The digits will flash if it exceeds the set values. The protection will start after 7 seconds under frequency or 3 seconds over frequency. After the
protection is enabled , the digits will keep flashing and show current protection value.
Automatic Overload Protection
Exceeds set power less than 5%, protection is disabled;
Exceeds set power more than 5%, power digits start flashing;
Exceeds set power 5% to 7.5% 3 hours continuously, protection is enabled.
Exceeds set power 7.5% to 10% 1 hour continuously, protection is enabled.
Exceeds set power more than 10%, protection is enabled immediately (about 2 seconds)
After the protection is enabled, the digits will keep flashing and show current protection value.
Automatic Engine Oil Protection
When the generator loses oil pressure, the oil circuit will switch off.
Automatic Shutdown
The system will shutdown and cut off fuel supply automatically when the conditions of automatic protection are necessary.
Manual Shutdown
Turn the key from ‘ON’ to ‘OFF’ position for complete shutdown.
Breaker
6A
6B
Toggle
Switch
120V/240V