Product Manual
Introduction
The Pro Series Pair of Pumps combination system
is designed to provide both primary and backup
pumping capabilities. The primary pump will
operate as long as it is receiving AC power. If the
power is interrupted, or more water is coming
into the sump than the AC pump can handle, the
backup sump pump will begin pumping
automatically. The backup system has unique
monitoring features that diagnose a problem and
sound an alarm. A light on the display panel of
the control unit will indicate the cause of the
alarm and the corrective action. The two systems
have been pre-assembled for easy installation.
To extend the battery run time, two batteries may
be connected to the Pro Series C33 system by
purchasing a second battery and acid pack, as
well as a set of battery jumper cables. Jumper
cables specifically designed for this use are
available from the manufacturer, Glentronics, Inc.
The Pair of Pumps Combination Sump Pump
System includes:
• A 1/3 HP primary pump with a caged dual
float switch, and a blue piggyback controller
that plugs into the wall outlet
• A gray backup pump
• A control unit with a battery fluid sensor, a
dual float switch, battery cables, and an
internal 13 amp charger
• A battery cap with a hole to accommodate
the fluid sensor
• A battery box
• A rubber union or no hub coupling
You will also need to supply:
• A Pro Series B-2200 or B12-90 standby
battery.
Pro Series standby batteries are specifically
designed to work with your battery backup
sump pump system. Glentronics can not
guarantee the compatibility of other brands
of batteries. For optimal performance the
use of a Pro Series standby battery is highly
recommended.
• DO NOT use an automotive battery with this
system
• DO NOT use a Pro Series 1000 battery with
this system. It will not run the pump as long
as the Pro Series B-2200 or B12-90 battery
• A surge protector (recommended for the
backup controller)
•
Six (6) quarts of 1.265 specific gravity battery
acid (if using a wet cell standby battery)
For some installations you may need
additional items:
• 1-1/2” rigid PVC pipe to connect to the
existing plumbing
• A PVC pipe connector or a rubber union
• PVC pipe cleaner and cement
To connect two batteries you will need:
• Two (2) batteries of same type, age and
capacity (so they will have equal power and
charge properly). Do not use batteries of
different types, ages or capacities.
• Another battery box
• Two (2) acid packs to fill the dry batteries.
Acid packs are not needed if using
maintenance free (AGM) batteries
• A set of battery cables with rings on both
ends to connect the two batteries together
(available from Glentronics, Inc.)
System Specifications
Power supply requirements.......115 volts, 60 Hz
AC pump pumping capacity......3000 GPH @ 10’
..............................................50 GPM @ 10’
DC pump pumping capacity......2400 GPH @ 10’
..............................................40 GPM @ 10’
Overall dimensions..................11” W x 23¾” H
Page 2
No Hub
Coupling
Primary Pump Controller
Backup
Pump
Controller
Primary
Pump
Battery Cables
Fluid Sensor
Battery Cap
Backup Pump
Float Switch
Backup
Pump
Battery Box
Primary
Pump Float
Switch