MT-1232 3-3/4 Autorange Digital Multimeter User’s Manual st , 1 Edition 2013 ©2013 Copyright by Prokit’s Industries Co., Ltd.
Contents General------------------------------------------------------------------1 Open-Package Inspection------------------------------------------2 Safety Note -------------------------------------------------------------2 Instrument Panel& Button Function Description---------------5 Other Functions--------------------------------------------------------6 Properties----------------------------------------------------------------6 Instrument Maintenance--------------------------------------------16 Fault
Open-package Inspection Open the package box and take out the meter, check carefully if the following accessories are missing or damaged. If there is anything missing or damaged, please contact the distributor immediately. Digital multimeter 1 PC User’s manual 1 copy Test leads 1 pair Temperature Probe (K-Thermocouple) 1 PC Test Socket 1PC Safety Note The design of this meter is in accordance with IEC1010 clause (the safety standard issued by International Electrotechnical Commission).
specification fuse can be replaced. Before the replacement, the test leads must be removed from the measuring point and ensure there is no any signal at the input terminal. 5. Don’t use other unconfirmed or disapproved battery to replace the battery inside the meter. Only the same model or same electrical specification battery can be replaced. Before the replacement, the test lead must be removed from the measuring point and ensure there is no any signal at the input terminal. 6.
12. 13. 14. 15. function must be in accordance with LCD display. Please be sure to disconnect the line of the test lead with the measured object first and ensure there is no any input signal. It is forbidden to switch the function/range selection switch during measurement When “ ” is shown on LCD display, please replace battery immediately to ensure the measurement precision.
Instrument Panel & Function Button Description 1. Instrument model number 2. LCD Display: Displays the measured data and unit. 3. Function Button 3.1 Hz/% (Frequency/Duty Cycle) Press this button to select the frequency or duty cycle mode. The measurement mode of voltage/frequency/duty cycle or current/frequency/duty cycle could be selected by pressing this button in AC/DC voltage or AC/DC current . 3.
5.2.10A“+”input terminal. 5.3. Voltage, Diode, Resistance, Capacitance, Frequency, Buzzer, Temperature and“+” Input terminal with current less than 400mA. Other Functions Auto Power off During measurement, the meter will automatically shut down (enter sleeping mode) to save power if function buttons and knob switch are not operated for 15 minutes.
Technical Features 2-1. Accuracy: ± (a%× reading +digits),at (23±5)˚C, relative humidity<75%. One year calibration guarantee from the time dispatched from the factory. 2-2. Technical Specification 2-2-1. DCV A) Turn the knob switch to “ “Range B) The default state of the meter is automatic range status, which shows “AUTO” symbol C) Put the test lead in contact with the testing point. The voltage and polarity of the point where the red pen is contacted will be displayed on the screen. Caution: 1.
2-2-2. ACV A) Insert black test lead into the hole of “COM” and red test “ lead into “ “, press “SELECT” button to Rotate function switch to “ select the AC measurement mode. C) The default state of the meter is in automatic range status, which shows “AUTO” symbol D) Put the test lead in contact with the testing point. The voltage of the point where the red test lead is contacted will be displayed on the screen. B) Caution: Don’t measure voltage over 600V. ; Otherwise, the meter will be damaged. 2.
2-2-3. DCA A) Insert the black test lead into the “COM” input terminal and red test lead into the “ “input terminal. (Max 400mA), or 10A input terminal (Max 10A). B) Rotate function switch to Current. The default state of the meter is in automatic range status, which shows “DC” symbol. Then connect the test lead to the tested circuit in series, the tested current value and the current polarity of the point where the red pen is contacted will be displayed on the screen simultaneously.
2-2-4. ACA A) Insert the black test lead into the “COM” input terminal and red test lead into the “ “input terminal. (Max 400mA), or 10A input terminal (Max 10A). B) Rotate function switch to Current. Press “SELECT” button to select the AC measurement mode. Then connect the test lead to the tested circuit in series, the tested current value and the current polarity of the point where the red test lead is contacted will be displayed on the screen simultaneously. Caution: 1.
2-2-5. Resistance (Ω) A) Insert the black test lead into “COM” terminal and red test lead into “ “terminal. B) Rotate the Range to “Ω”. Cross connect the two test leads to the tested resistor. C) When measuring the low resistance, please short-circuit the test leads at first to test the wire resistance, and then deduct it from the actual resistance. Caution: 1.
2-2-6.Diode and Continuity Test A) Insert the black test lead to “COM” terminal and the red test lead to “ ” terminal. (The polarity of red test lead is“+”). B) Rotate the Range to “ “. Press “SELECT” button to select the Diode measurement mode. C) Forward Measurement: Connect the red test lead to the diode positive polarity and the black test lead to the diode negative polarity. The approximate value of diode forward voltage drop will show on the display. 4.
2-2-7. Capacitance (F) A) Rotate function switch to “ “. B) Insert the black test lead to “COM” terminal and red test lead to “ “ terminal or insert the test socket. C) Connect the tested capacity by the test leads to “COM”, “ “ input terminal or insert the test socket hole Cx - / +, the screen will show capacitance parameter. (The relative value measurement could be conducted by pressing “REL” button.) Caution: 1. Fully discharge the tested capacitor in case it damages the meter. 2.
2-2-8. Frequency (Hz) A) Connect test leads and shielded cable to “COM”, “ ” terminals. B) Rotate function switch to “Hz”. Connect test leads and the cable to the signal source or the tested load. The tested signal will show on the screen. Caution: 1. When inputting AC RMS over 10V, it could show reading, but excess vibration may appear. 2. It is recommended to test weak signals by shielded cable under noisy circumstances. 3. Select ACV when testing the frequency of high voltage.
2-2-9. Temperature (˚C) A) Rotate function switch to (˚C). B) Insert the cathode (black pin) of cold end (free end) of thermocouple into “COM” jack and anode into “ ” terminal. Then put the working end (temperature measurement end) of thermocouple on the surface or inside the object to be tested. Then you can read temperature from the screen, and the data is in Centigrade. Caution: 1. When the input terminal is open-circuit, it will display the normal temperature. 2.
Instrument Maintenance This is a precision instrument and the user shall not modify the electric circuit as well. 1. Keep the instrument away from water, dust and shock. 2. Do not store and operate the meter under the condition of high temperature, high humidity, combustible, explosive and strong magnetic place. 3. Wipe the case with a damp cloth and detergent; do not use abrasives and alcohol. 4. If the instrument is not operated for a long time, please take out the battery to avoid leakage. 5.
Fault Elimination If the instrument does not work properly, please try the following tips to solve some general problems. If the problems still exist, please contact the maintenance center or the distributor. Fault Solution Turn on power. No Display Replace battery symbol appearance Big display error Replace battery. Replace battery • This Instruction is subject to change without any further notice.
目 錄 一.概述-------------------------------------------------------------------------18 二.開箱檢查-------------------------------------------------------------------18 三.安全注意事項-------------------------------------------------------------19 四.儀錶面板及按鍵功能說明---------------------------------------------20 五.其他功能------------------------------------------------------------------- 21 六.特性------------------------------------------------------------------------- 21 七.
三、安全注意事項 該儀錶在設計上符合 IEC1010 條款(國際電工委員會頒佈的安全標 準),在使用之前,請先閱讀安全注意事項。 1. 在測量直流 36V、交流 25V 以上電壓,測量 10mA 以上電流,測 量帶電感負載的交流電力線;測量電力波動期間的交流電力線 時, 謹防電擊。 2. 測量前,檢查測量功能開關是否置於正確的檔位,要檢查錶筆 是否可靠接觸,是否正確連接、是否絕緣良好等,以避免電 擊。 3. 儀錶只有和所配備的錶棒一起使用才符合安全標準要求。如 錶棒線破損時,必須更換上同樣型號或者相同電氣規格的錶棒 線 4. 不要使用其他未經確認或未認可的保險管來更換儀錶內部的 保險管。只能換上同樣型號或相同規格的保險管。更換前,錶 棒必須離開被測量點,確保輸入端無任何信號。 5. 不要使用其他未經確認的電池來更換儀錶內的電池。只能換 上同型號或相同電氣規格的電池。更換前,錶棒必須離開被測 量點,確保輸入端無任何信號。 6. 在進行電氣測量時,身體切勿直接接觸大地,不要接觸可能存 在地電勢裸露的金屬端子、輸出口、引線夾等。通常使用乾 燥的衣服、膠鞋、膠墊以及其他絕緣材料,保持你的身體與大 地絕緣。 7.
11. 在測量時功能/量程選擇開關必需置於正確的量程檔位,在轉 換功能/量程選擇開關時,請一定要先將錶棒線與被測物件斷 開,確保輸入端沒任何信號輸入。嚴禁在測量進行中轉換功能/ 量程選擇開關。 12. 當 LCD 顯示“ "時,請及時更換電池以確保測量精度。 13. 不允許在電流檔去測量電壓! 14. 請不要隨意改變儀錶線路,以免損壞儀錶和危及安全。 15. 安全符號說明: 警告! 直流電壓 高壓!危險! 交流電壓 直流電流 大地 交流電流 符合歐洲工 雙重絕緣 會指令 低電壓指示 保險絲 四、儀錶面板及按鍵功能說明 1. 儀錶型號 2. 液晶顯示器:顯示儀錶測量的數值 及單位 3. 功能按鍵說明 3.1. Hz/% : (頻率/占空比):在頻率檔 觸發此鍵, 可選擇頻率或占空比 測量模式.
3.2. REL: (相對值測量):在電 容檔觸發此鍵, 可進行相對值測量模式. 3.3. D/¤ : (數據保持/背光功能):觸發此鍵左側時, 鎖定數值功能, 顯示值被鎖定, 一直保持不變. 再按此鍵(左側)時, 鎖定狀 態被解除, 進入正常狀態。 觸發此鍵右側大於 3 秒, 背光功 能實現. 再觸發此鍵(按右側)關閉背光. 3.4 S: (功能切換): 觸發此鍵時,功能會在 DC/AC 之間切換 4. 旋鈕開關:用於改變測量功能及量程。 5. 輸入插孔 5.1. 電流、電壓、二極體、電阻、電容、頻率、蜂鳴器、溫度的 “-"輸入插孔 5.2. 10A“+"輸入插孔 5.3. 電壓、二極體、電阻、電容、頻率、蜂鳴器、溫度“+"及 小於 400mA 電流的輸入插孔 五、其他功能 自動關機 在測量過程中,功能按鍵和撥盤開關在 15 分鐘內均無動作時, 儀錶會“自動關機"(休眠狀態),以節約電能;在自動關 機狀態下,按動功能鍵或是轉動撥盤開關,儀錶會“自動開 機"(工作模式) 六、特性 1.一般特性 1-1. 顯示方式:液晶顯示 1-2. 最大顯示:3999(3 3/4 位元)自動極性和單位顯示 1-3.
1-8. 相對溫度:(0~50)℃,相對濕度<80% ; 1-9. 電源:兩節 1.5V 電池(“AA"電池) ; 1-10. 體積(尺寸):147×78×41mm (長×寬×高) 1-11. 重量:約 183g 1-12. 附件:使用說明書一本、外包裝盒各一個,10A 錶棒一付、 K 型熱電偶線一條、電晶體測試座一個。 2.技術特性 2-1. 準確度:±(a%×讀數+字數),保證準確度環境溫度:(23±5)°C,相 對濕度<75%,校準保證期從出廠日起為一年。 2-2. 性能 功能 有/無 直流電壓 DCV 有 交流電壓 ACV 有 直流電流 DCA 有 交流電流 ACA 有 電阻 Ω 有 電容 CAP 有 頻率 Hz 有 二極體/通斷 有 溫度 °C 有 2-3-1.直流電壓(DCV) A). 將功能開關轉至“ "檔 B). 儀錶初始為自動量程狀態,顯示“AUTO"符號 C.) 將測試錶棒接觸測試點,紅錶棒所接的該點電壓與極性顯示在 螢幕上。 注意: 1. 測量電壓切勿超過 600V,超過則有損壞儀錶電路的危險。 2.
量程 400mV 4V 40V 400V 600V 準確度 ±(0.5%+4d) ±(1.0%+4d) 分辨力 100uV 1mV 10mV 100mV 1V ‧輸入阻抗:400mV 大於 40MΩ;其餘為 10MΩ。 ‧超載保護:600V 直流或 600V 交流峰值; 2-3-2.交流電壓(ACV) 1.將黑錶棒插入“COM"插孔,紅錶棒插入“ "插孔; 2.將功能開關轉至“ "檔,按動“SELECT"鍵選擇 AC 測量方 式 3.儀錶初始為自動量程狀態,顯示“AUTO"符號; 4.將測試錶棒接觸測試點,紅錶棒接的該點電壓顯示在螢幕上。 注意: 1. 測量電壓切勿超過 600V,如超過,有損壞儀錶電路的危險。 2. 當測量高電壓電路時,千萬注意避免人體觸及高壓電路,注意 人身安全。 量程 準確度 分辨力 ±(0.8%+6d) 4V 1mV 40V 10mV 400V 100mV 600V ±(1.
2-3-3.直流電流(DCA) A) 將黑錶棒插入“COM"插孔,紅錶棒插入“ "插孔(最 大為 400mA),或插入“10A"插孔中(最大為 10A) B) 將功能開關轉至電流檔,儀錶初始為自動量程狀態,顯示 “DC"符號,然後將儀錶的錶棒串入被測電路中,被測電流 值及紅色錶棒點的電流極性將同時顯示在螢幕上。 注意: 如 LCD 顯示“OL",表明已超過量程範圍,需將量程開關轉 至較高一檔。 2. 最大輸入電流為 400mA 或者 10A(視紅錶棒插入位置而定), 超過額定的電流會將保險絲熔斷,甚至損壞儀錶。 量程 準確度 分辨力 ±(1.0%+10d) 400uA 0.1uA 4000uA 1uA 40mA 10uA 400mA 100uA 10A ±(1.2%+10d) 10mA ‧最大測量壓降:滿量程 mA 為 0.4V,A 為 100mV; ‧最大輸入電流:10A(不超過 15 秒); ‧超載保護:0.4A/250V 自恢復保險絲,10A/250V 保險管。 1. 2-3-4.交流電流(ACA) 1.
注意: 如 LCD 顯示“OL",表明已超過量程範圍,需將量程開關轉 至較高一檔。 2. 最大輸入電流為 400mA 或者 10A(視紅錶棒插入位置而定), 超過額定的電流會將保險絲熔斷,甚至損壞儀錶。 量程 準確度 分辨力 ±(1.5%+10d) 400uA 0.1uA 4000uA 1uA 40mA 10uA 400mA 100uA 10A ±(2.5%+15d) 10mA ‧最大測量壓降:滿量程 mA 為 0.4V,A 為 100mV; ‧最大輸入電流:10A(不超過 15 秒)。 ‧超載保護:0.4A/250V 自恢復保險絲,10A/250V 保險管。 ‧頻率回應:10A 量程為(50~200)Hz。 1. 2-3-5.電阻(Ω) 1.
量程 準確度 分辨力 400Ω ±(0.8%+5d) 0.1Ω ±(0.8%+4d) 4kΩ 1Ω 40kΩ 10Ω 400kΩ 100Ω 1kΩ 4MΩ 40MΩ ±(1.2%+10d) 10kΩ ‧開路電壓:小於 200mV; ‧超載保護:250V 直流或交流峰值; ‧注意事項:在使用 400Ω 量程時,應先將錶棒短路,測得引線電 阻,然後在實測中減去 2-3-6.
量程 顯示值 二極體正向壓降 蜂鳴器發聲長響,測 試兩點阻值約 50Ω ‧超載保護:250V 直流或交流峰值; 測試條件 正向直流電流 0.5mA 反向 電壓約 1.5V 開路電壓約 0.5V 警告:為了安全在此量程禁止輸入電壓值! 2-3-7.電容(F) 1. 將功能開關轉至“ "檔; 2. 將黑錶棒插入“COM"插孔,紅錶棒插入“ 或將錶棒換為測試座插入。 3. " 插孔, 用測試錶棒(注意紅錶棒極性為正極)將被測電容接入 “COM〞〞 "輸入端或插入測試座 Cx-/+孔中,螢幕將顯 示電容容量。(按動“REL"鍵可進行相對值測量) 注意: 1. 對被測電容應完全放電,以防止損壞儀錶; 2. 測量線上電容時,需將線路電源關斷,並將電容充分放電; 3. 100uF 量程輸入讀數穩定時間約 30 秒。 量程 準確度 分辨力 4nF ±(5.0%+9d) 1 pF ±(3.5%+8d) 40nF 10pF 400nF 100pF 4μF 1nF 40μF 10nF 100μF ±(5.
2-3-8.頻率(Hz) 1. 將錶棒或遮罩電纜接入“COM"、“ "輸入端; 2. 將功能開關轉至“Hz"檔,將錶棒或電纜跨接在信號源或被測 負載上,被測信號的頻率顯示在螢幕上。 注意: 輸入超過 10V 交流有效值時,可以讀數,但可能超差; 在雜訊環境下,測量小信號時最好使用屏壁電纜; 測量高電壓的頻率時,請選擇 ACV 檔,再按 Hz/DUTY 按鍵 進入頻率測量狀態 4. 禁止輸入超過 250V 直流或交流峰值的電壓,以免損壞儀錶。 程量 準確度 分辨力 1Hz ±(0.5%+10d) 0.001Hz 10Hz 0.01Hz 100Hz 0.1Hz 1kHz 1Hz 10kHz 10Hz 100kHz 100Hz 1MHz 1kHz 10MHz 10kHz 0.1-99.9% 僅供參考 0.1V ‧ 輸入靈敏度:>0.7V 有效值 ‧ 超載保護:250V 直流或交流峰值。 1. 2. 3. 2-3-9.溫度(°C) 1. 將功能開關轉至“℃"檔. 2.
注意: 1. 當輸入端開路時,則顯示常溫。 2. 請勿隨意更換測溫感測器,否則將不能保證測量準確度。 3. 嚴禁在溫度檔測量電壓。 量程 準確度 分辨力 (-20~1000)˚C <400˚C±(1.0%+5d) 1˚C ≥400˚C±(1.5%+15d) 感測器:K 型熱電偶(鎳鉻—鎳矽)香蕉插頭。 警 告:為了安全在此量程禁止輸入電壓值! 七、儀錶保養 該儀錶是一台精密儀器,使用者不要隨意更改電路。 1. 請注意防水、防塵、防摔 2. 不宜在高溫高濕、易燃易爆和強磁場的環境下存放、使用儀 錶 3. 請使用濕布和溫和的清潔劑清潔儀錶外表,不要使用研磨劑 及酒精等烈性溶劑 4. 如果長時間不使用,應取出電池,防止電池漏液腐蝕儀錶 5. 注意 1.5V 電池使用情況,當螢幕顯示出“ "符號時,應 更換電池,步驟如下: 5-1. 卸下固定電池盒的螺絲,取出電池盒 5-2. 取出 1.5V 電池,換上兩個新的電池,雖然任何標準 1.5V 電池都可使用,但為加長使用時間,最好使用鹼性電池 5-3.
注意: 不要將 1000V 直流或交流峰值電壓接入 不要在電流檔、電阻檔、二極體檔和蜂鳴器檔上,測量電壓 值 3. 在電池沒有裝好或後蓋沒有上緊時,請不要使用此錶 4. 在更換電池或保險絲前,請將測試錶棒測試點移開,並關機。 1. 2.
©2013 Prokit’s Industries Co., LTD.