Owner`s manual

- 3 -
CO GAS EXPOSURE VERSUS TIME
(400 PPM EXPOSURE)
MINUTES RESPONSE
8 NONE
15 NONE
25 SLIGHT HEADACHE
35 HEADACHE
45 HEADACHE AND NAUSEA
60 DROWSY
75 VOMITING
90 COLLAPSE
110 COMA AND PERMANENT
BRAIN DAMAGE
140 PERMANENT BRAIN
DAMAGE – DEATH
2. SPECIFICATIONS
CO RESPONSE TIME @ 70 PPM
@150 PPM
@ 400 PPM
60~240 MINUTES
10~50 MINUTES
4~15 MINUTES
POWER SOURCE 9V Battery
OPERATING TEMPERATURE 40
o
F (4.4
o
C) TO 100
o
F (37.8
o
C)
ALARM 85 dB AT 10 FEET
DETECTION FREQUENCY SAMPLES EVERY 2 MINUTES
LCD DISPLAY (FOR MODELS 7035/SL):
1. DIGITAL READ-OUT OF CURRENT
CO DETECTED AND PEAK LEVEL
MEMORY
FROM 0 PPM TO 500 PPM, WILL FLASH "500"
IF LEVEL EXCEEDS 500 PPM.
2. PEAK LEVEL TIME RECORD (THE
TOTAL TIME CO IS DETECTED
WITHIN 10% OF THE PEAK LEVEL)
FROM 0 TO 999 MINUTES, WILL FLASH “999”
IF LEVEL EXCEEDS 999 MINUTES.
3. COHb RANGE
(CARBOXYHEMOGLOBIN)
FROM 0.0% TO 99.9%, WILL FLASH “99.9%” IF
LEVEL EXCEEDS 99.9 %.
DISPLAY TOLERANCE @ 50% RH,
22°C±3°C IN UPRIGHT POSITION
± 30% @ 30-500 PPM
BATTERY TYPE LONG-LIFE ULTRALIFE U9VL-J LITHIUM
POWER CELL
400 PPM EXPOSURE
50%
45%
40%
35%
30%
25%
20%
15%
10%
5%
0%
C
O
H
b 1
0
0
%
8 15 25 35 45 60 75 90 110 140
Minute
s