4. WARNING! LOCATIONS TO AVOID:
NEAR THE COOKING AREA: CO may be generated in the cooking process and cause
nuisance alarms. Also cooking grease can build up on the alarm and cause alarm failure.
CLOSE TO A FURNACE, WATER HEATER, OR SPACE HEATER: These devices
often spill out small amounts of CO when they first turn on.
IN GARAGES: Automobile exhaust contains CO and will activate alarm.
IN DUSTY AREAS: Dust can build up on the alarm and cause failure to alarm.
IN CLEANING SUPPLY ROOMS: Chemicals used in household cleaning and painting
supplies can cause nuisance alarms.
IN VERY HOT OR COLD AREAS: Do not install the alarm in areas which are below
40
o
F (4.4°C) or above 100
o
F (37.8°C).
IN HAZARDOUS LOCATIONS: This alarm is not suitable for installation in a hazardous
location, as defined in the National Electrical Code.
5. INSTALLATION INSTRUCTIONS:
NOTE: REVIEW SECTION 3, RECOMMENDED LOCATIONS OF ALARMS AND
SECTION 4, LOCATIONS TO AVOID, PRIOR TO INSTALLING YOUR ALARM.
ϖ The proper power for the 7030/SL and 7035/SL CO alarms is a 9V battery.
ϖ Constant exposure to high or low humidity may reduce battery life.
BATTERY INSTALLATION AND REPLACEMENT 7030/ 7035:
ϖ Open the battery door (to remove the old battery for replacement) and attach a new
9 Volt battery (Use Ultralife U9VL-J only) to the battery cable. Battery must snap
firmly onto both connectors.
ϖ Press the battery reminder lever down, then place the battery on top of the lever in
the battery compartment and close the battery door.
ϖ Press the TEST/RESET button to verify activation. (See TESTING in section 6)
BATTERY INSTALLATION AND REPLACEMENT 7030SL/ 7035SL:
ϖ Loosen the security screw on the battery door with the provided allen key (enclosed
in the box)
ϖ Open the battery door (to remove the old battery for replacement) and attach a new
9 Volt battery (Use Ultralife U9VL-J only) to the battery cable. Battery must snap
firmly onto both connectors.
ϖ Press the battery reminder lever down, then place the battery on top of the lever in
the battery compartment.
ϖ Close the battery door, and fasten the security screw into it. (Keep the allen key for
future use)
ϖ Pull the Power Tab completely out of the unit to activate the alarm. Press the
TEST/RESET button to verify activation. (See TESTING in section 6)
WARNING! DO NOT USE RECHARGEABLE BATTERY, OR ANY OTHER
TYPE OF BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL.
CAUTION! IF THE BATTERY DOES NOT HOLD DOWN THE REMINDER
LEVER IN THE BATTERY COMPARTMENT, THE BATTERY DOOR WILL NOT
CLOSE AND THE ALARM WILL NOT MOUNT TO THE MOUNTING PLATE.