Owner`s manual

- 7 -
MOUNTING INSTRUCTIONS:
FOR 7030/ 7035:
ϖ After selecting the proper alarm
location as described in SECTION 3,
drive a screw into the wall at eye
level leaving the screw-head about
¼ inches from the wall.
ϖ Hang the alarm firmly onto the
screw-head.
1/4”
FOR 7030SL/ 7035SL:
ϖ Remove the mounting plate from the
back of the alarm (slide to the unlock
position to remove).
ϖ After selecting the proper alarm
location as described in SECTION 3,
fasten the mounting plate to the wall.
Slide the alarm down onto the mounting
plate, and secure it with a screw through
the flange on the top of the alarm.
After installation TEST your alarm by pressing and holding the TEST / RESET button for
several seconds. Complete instructions regarding testing are outlined in SECTION 6.
CAUTION! CO detection is best achieved by the installation of CO detection
equipment in all rooms and areas of the household.
6. OPERATION, TESTING:
OPERATION: The CO alarm is operational once a battery is installed and testing is
complete. The green LED will blink once per minute.
SERVICE (TROUBLE) CONDITION: The internal microcontroller continuously
monitors the sensor and other critical components. If an internal failure of any of these
components should occur, the alarm will sound 2 short beeps per minute and the red
LED will flash twice during the beeping. The trouble condition indicates a problem with
the unit. Please see SECTION 11 for information regarding service.
LIFE MONITOR: The electrochemical sensor has an estimated life expectancy of 5
years. The microcontroller monitors the total time that the alarm is under power. After 5
years, the “trouble” signal will activate, indicating that the sensor life has expired.