Specifications

CD-312
PRO WELD
9.3
Cuphead and Power Point pin hook
-
up (see Figure 4)
A. Connect ground cable connector (1A) into camlok (1). The camlok should
be connected into the
receptacle marked CUPHEAD. Twist until it locks. Attach ā€œCā€ clamp (2) to the workpiece (5)
(CLEANED AREA)
.
B. Connect the gun control cable (3A) into the female receptacle (3).
C. Connect the gun weld cable (4A) into the receptacle
marked GUN (4). Twist clockwise until it
locks.
D. Connect AC power cable to AC outlet.
NOTE:
The gun welding and control cab
les must be laid out in a straight line. Poor weld quality may result if
welding cables are coiled.
Figure 4 Cuphead Pin Hook
-
Up
3
3A
4A
4
1
1A
2
5
PAGE 6