Pro1 Installation Manual

ProgrammingProgramming
Tech Settings Tech Settings
You can congure this thermostat
to have 7 Day, 5+1+1 program-
ming or non programmable.
Program
Options
5d
Use the and key to se-
lect 7d for 7 Day, 5d for 5+1+1,
or 0d for non programmable.
Tech Settings
Adjustment Options Default
LCD Will Show
Set Time
1. With system switch set to OFF, press the MENU button
2. Press SET TIME
3. Day of the week will be ashing. Use the or key
to select the current day of the week.
4. Press NEXT STEP
5. The current hour is ashing. Use the or key to
select the current hour. When using 12-hour time, make sure
the correct a.m. or p.m. choice is selected.
6. Press NEXT STEP
7. Minutes are now ashing. Use the or key to
select current minutes.
8. Press DONE when completed.
(If using programming)
Programming
All of our programmable thermostats are shipped with an
energy saving pre-program. You can customize this default
program by following the steps on page 16.
There are four time periods for each program (WAKE, LEAVE,
RETURN, SLEEP).
Set Program Schedule 5+1+1 or 7 Day
1. Select HEAT or COOL with the system switch. Note: You have
to program heat and cool each seperately.
2. Press the MENU button (If menu does not appear rst press RUN SCHED)
3. Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Day)
is displayed and the WAKE icon is shown. You are now
programming the wake time period for that day.
4. Time is ashing. Use the or key to make your time
selection for that day’s WAKE time period.
5. Press NEXT STEP
6. The setpoint temperature is ashing. Use the or key
to make your setpoint selection for that day’s WAKE time
period.
7. Press NEXT STEP
8. Repeat steps 4 thru 7 for that day’s LEAVE time period,
RETURN time period, and SLEEP time period.
To customize your program schedule, follow these steps:
You can congure the thermostat to
operate a 3 stage heat pump system.
2H 2C = 2 heat, 2 cool
3H 2C = 3 heat, 2 cool
This feature only shows if Technician
Setup Step for HEAT PUMP is set
to ON.
Use the or key to
change between 2H and 3H.
2H will use Y1 as rst stage
and W2 as auxiliary.
3H will use Y1 as rst stage,
Y2 as second stage and W2 as
auxiliary.
Stages of
Heat
2H
The cooling fan delay setting will
delay the fan from coming on in
cool mode and keep running after
the compressor shuts o for a
short time to save energy in some
systems.
You can select the cooling fan
delay from “OFF”, “15”, “30”, “60”
or “90” seconds. If 15, 30, 60 or
90 is selected the fan will not
turn on for that many seconds
when there is a call for cool and
will run for that many seconds
after satisfying a call for cool.
Cooling
Fan Delay
OFF
Next Step
Prev Step
Next Step
Prev Step
You can select either a 12 or 24 hour
clock setting.
12 or 24
Hour Clock
12
Use the and to select 12
or 24 hour clock.
Select GAS for systems that control
the fan during a call for heat. Select
ELEC to have the thermostat control
the fan during a call for heat.
Fan
Operation
GAS
GAS - GS
or
ELEC - EL
CLOK
Next
Prev
Done
FAN
Next
Prev
Done
GA
PROG
Next
Prev
Done
5d
When turned on the thermostat will
operate a heat pump.
1. EM. Heat will show as an option in
the system switch.
2. Y will be rst stage of heat & cool,
W/E will be emergency heat relay &
W2 will be axiliary heat relay.
Heat Pump
OFF congures the thermostat
for non-heat pump systems.
ON congures the thermostat
for heat pump systems.
HPUM
Next
Prev
Done
OF
Tech Settings
Adjustment Options Default
LCD Will Show
For Dual Fuel applications (Gas/
Fossil fuel Auxiliary Heat), turn this
setting ON to LOCKOUT the Heat
Pump (Y) when Auxiliary Heat (W2)
is on. If desired - This can also be
used with Electric Auxiliary.
OFF
OFF Will allow Y(1st stage of
Heat) and W2 (Aux Heat) to run
together if called for.
ON Will de-energize Y terminal
45 seconds after a call for
Auxiliary Heat (W2).
You can congure the system switch
for the particular application:
Heat - O - Cool, Heat - O, Cool
- O.
Note: EM. Heat will show if in heat
pump mode.
System
Switch
Heat
O
Cool
SYST
Next
Prev
Done
GAUX
Next
Prev
Done
OF
Use the or key
until the desired application is
ashing.
Cool
Heat O
This feature allows the thermostat to
keep multiple stages of heat or cool
energized until setpoint is satised
for that cycle.
Use the or key to turn
ON or OFF.
Satisfy
Setpoint
OFF
This feature allows a delay to occur
when a second stage is needed.
This allows the previous stage extra
time to satisfy setpoint.
Use the or key to
select OFF, 10, 15, 30, 45, 60, or
90 minutes.
Staging
Delay
OFF
Next Step
Prev Step
Next Step
Prev Step
HPUM
2H
FNdL
OF
OFF
OF
5d
OF
Dual Fuel
Auxiliary
for Heat
Pump
Will only
appear if
Heat pump
setting is
turned ON.
Repeat steps 4 thru 8 for the Saturday + Sunday time
periods.
If in 5+1+1 Programming:
Use these same steps for every individual day.
If using 7- Day Programming: