Operating instructions
OPERATION
980076 08/26/03
3-15
DANGER
WATER UNDER HIGH PRESSURE AT HIGH
TEMPERATURE CAN CAUSE BURNS,
SEVERE PERSONAL INJURY, OR COULD
BE FATAL. SHUT DOWN MACHINE,
ALLOW TO COOL DOWN, AND RELIEVE
SYSTEM OF ALL PRESSURE BEFORE
REMOVING VALVES, CAPS, PLUGS,
FITTINGS, FILTERS AND BOLTS.
DANGER
DO NOT MODIFY
UNIT WITHOUT
WRITTEN
PERMISSION
FROM
MANUFACTURER
ROTATING
MACHINERY.
WATER UNDER
PRESSURE AT HIGH
TEMPERATURE.
IMPROPER
MODIFICATION OF
EQUIPTMENT CAN
CAUSE SEVERE
PERSONAL INJURY
OR COULD BE
FATAL.
Operate this unit and
equipment only in a well-
ventilated area. Exhaust fumes contain carbon
monoxide which is an odorless and deadly
poison that can cause severe injury or fatality.
DO NOT operate this unit where the exhaust may
enter any building doorway, window, vent, or
opening of any type.
Install the stack outlet adapter on the stack outlet
to exhaust the engine and combustion gases
upward.
CHECK FOR ADEQUATE FUEL
Check the burner fuel tank to be certain there is
adequate fuel to complete the job. This unit uses
approximately .75 gallons of fuel per hour,
depending on the speed setting.
Check to make sure your fuel burner tank is full.
REMOVE TOOLS FROM VEHICLE
Remove any tools or hoses from the van which you
will require.
WATER SUPPLY CONNECTION
NOTE: Before connecting your water hose to the
supply faucet, flush out the faucet until the water
is free of any debris. Flush out any debris which
may be in your water inlet hose.
1. Connect the water supply hose to the water
inlet quick-connect at the front of the unit.
Connect the hose to the water supply faucet.
NOTE: Never use your waste pump outlet hose
as a water inlet hose. Use only clean hoses for
water inlet.
2. Turn the water supply faucet on. The water will
fill the water box.
FILLING AUXILIARY WATER TANK
1. Your cleaning unit may be equipped with an
auxiliary water tank. To fill the auxiliary water
tank, remove cap from tank and fill with water
supply hose.
2. Connect the water supply hose to the water
supply faucet.
3. Turn the water supply faucet on and fill the
auxiliary water tank.
4. When the auxiliary water tank is full, plug in the
hose from the demand pump into the water
inlet quick-connect at the front of the unit.
5. Turn ON the toggle switch at the front of the
demand pump. NOTE: Make sure you turn on
the demand pump before you start the unit.
HIGH PRESSURE HOSE
Before starting the unit, connect the pressure hose
to the solution outlet connection at the front of the
unit. Connect the cleaning tool to the pressure
hose.