Instructions / Assembly

NG
3-3.5" WC
LP
8-11" WC
REPLACING THERMOCOUPLE (TC)
200500-01
Rev. A
09/18
ProCom Heating, Inc.
Bowling Green, KY 42101
www.usaprocom.com
1-866-573-0674
Dual Fuel Pilot
Thermostat
Controlled Valve
Manual
Controlled Valve
Solenoid
Controlled Valve
Single Fuel Pilot
Natural Gas
Burner
Propane
Gas Burner
Gas Burner
Thermocouple
Thermocouple
Retainer Bracket
Screw
Screw
Screws
Thermocouple
Location
Thermocouple
Location
Thermocouple
Location
Retainer Bracket
Ignitor
Electrode
Ignitor
Electrode
Turn off unit and let cool before ser-
vicing. Only a qualied service person
should service and repair heater.
Follow the instructions below to replace the ther-
mocouple to your unit. Refer to the illustrations to
locate parts.
1. Remove the 2 screws securing retainer bracket
to the pilot. Ignitor electrodes may detach from
the pilot when the bracket is removed. Be certain
to reinstall them in the correct position.
2. Remove the old thermocouple from the pilot.
Follow the tubing from the thermocouple to the
control valve. Unscrew the thermocouple from
the control valve.
3. Screw the end of the new thermocouple into the
control valve.
4. Position the wiring of the new thermocouple the
same way as the old thermocouple.
5. Place end of new thermocouple onto the pilot.
Secure thermocouple and ignitor electrodes with
retainer bracket and 2 screws removed in step 1.

Summary of content (1 pages)