Installation Guide
www.usaprocom.com
200068-01A14
INSTALLATION
Figure 13 - Gas Connection
Figure 12 - Attaching Flexible Gas Hose 
to Heater Gas Regulator
Typical Inlet Pipe Diameters
Use 1/2" black iron pipe or greater. Installa-
tion must include an equipment shutoff valve, 
union,  and  plugged  1/8"  NPT  tap.  Locate 
NPT tap within reach for test gauge hook up. 
NPT tap must be upstream from heater (see 
Figure 13).
IMPORTANT: Install an equipment shutoff 
valve in an accessible location. The equip-
ment shutoff valve is for turning on or shutting 
off the gas to the appliance.
For  propane/LP  installations,  apply  pipe 
joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. 
Excess sealant in pipe could result in clogged 
heater valves.
The installer must supply an external regula-
tor. The external regulator will reduce incom-
ing gas pressure. You must reduce incoming 
gas pressure to between 11" WC and 14" WC. 
If you do not reduce incoming gas pressure, 
heater regulator damage could occur. Install 
external regulator with the vent pointing down 
as shown in Figure 14. Pointing the vent down 
protects it from freezing rain or sleet.
Figure 14 - External Regulator 
with Vent Pointing Down
External 
Regulator with 
Vent Pointing 
Down
Propane/LP 
Supply Tank
Approved Flexible Gas Hose 
(if allowed by local codes)
CSA Design-Certied 
Equipment Shutoff Valve 
With 1/8" NPT Tap*
Flexible Gas Hose (if 
allowed by local codes)
Fitting
Heater Gas 
Regulator
Sediment Trap
Cap  Pipe  Tee
  Nipple  Joint
3" Minimum
Install sediment trap in supply line as shown 
in Figure 13. Place sediment trap where it is 
within reach for cleaning. Place sediment trap 
where trapped matter is not likely to freeze. 
A sediment trap traps moisture and contami-
nants. This keeps them from going into heater 
controls. If sediment trap is not installed or is 
installed wrong, heater may not run properly.
 WARNING: Test all gas piping 
and connections for leaks after 
installing or  servicing. Correct 
all leaks at once (see page 15).
Natural Gas
From Gas Meter 
(5" W.C.** to 10.5" 
W.C. Pressure)
Propane/LP 
From External 
Regulator 
(11" W.C.** to 14" W.C. 
Pressure)
* Purchase the optional CSA design-certied equipment 
shutoff valve from your dealer.