Installation Guide
www.usaprocom.com
3200068-01A
Only a qualied installer, service 
agent, or local gas supplier may 
install and service this product.
  WARNING:  Keep  the  appli-
ance area clear and free from 
combustible materials, gasoline, 
and other ammable vapors and 
liquids.
 WARNING: This  appliance 
is equipped for use with natural 
gas OR propane gas. Field con-
version is not permitted.
This  appliance  is  only  for  use 
with the type of gas indicated on 
the rating plate. This appliance 
is  not  convertible  for  use  with 
other gases.
 DANGER: Carbon monoxide 
poisoning may lead to death!
SPECIFICATIONS
SAFETY
Carbon Monoxide Poisoning: Early signs of 
carbon monoxide poisoning resemble the u, 
with headaches, dizziness or  nausea.  If you 
have these signs, the heater may not be work-
ing properly. Get fresh air at once! Have heater 
serviced. Some people are more affected by 
carbon monoxide than others. These include 
pregnant  women,  people  with  heart  or  lung 
disease or anemia, those under the inuence 
of alcohol and those at high altitudes.
Natural And Propane/LP Gas: Natural and 
Propane/LP gas are odorless. An odor-making 
agent is added to the gas. The odor helps you 
detect a gas leak. However, the odor added to 
the gas can fade. Gas may be present even 
though no odor exists.
 WARNING: Do not use a 
blower  insert,  heat  exchanger 
insert or any accessory not ap-
proved for use with this log set.
 WARNING: Do not allow fans 
to blow directly into the heater. 
Avoid any drafts that alter burner 
ame pattern  including  ceiling 
fans.  Altered burner  patterns 
can cause sooting.
MODEL
WZN18(HL,MV)A WZN24(HL,MV)A WZN30MVA
Ignition Piezo Ignitor Piezo Ignitor Piezo Ignitor
Gas Type Natural Natural Natural
Input Rating 32,000 BTU/Hr 34,000 BTU/Hr 40,000 BTU/Hr
Manifold Pressure 3" W.C. 3" W.C. 3" W.C.
Inlet Gas Pressure* 
(inches of water)
Max. 10.5" W.C. Max. 10.5" W.C. Max. 10.5" W.C.
Min. 5" W.C. Min. 5" W.C. Min. 5" W.C.
MODEL
WZL18(HL,MV)A WZL24(HL,MV)A WZL30MVA
Ignition Piezo Ignitor Piezo Ignitor Piezo Ignitor
Gas Type Propane/LP Propane/LP Propane/LP
Input Rating 32,000 BTU/Hr 34,000 BTU/Hr 40,000 BTU/Hr
Manifold Pressure 8" W.C. 8" W.C. 8" W.C.
Inlet Gas Pressure* 
(inches of water)
Max. 14" W.C. Max. 14" W.C. Max. 14" W.C.
Min. 11" W.C. Min. 11" W.C. Min. 11" W.C.
* For purposes of input adjustment.