User guide

BPF 3/...-200-SHT
Band-Pass Filter for the 130 MHz Band
DESCRIPTION
High power base station shortened band-pass filter for the 116 - 146
MHz range.
Due to the use of large ø200 mm cavities a high Q is achieved, resulting
in a very narrow passband.
The large dimensions also mean a high power rating.
The SHT-version has only 600 mm cavity length.
Unloaded Q of a single cavity is approx. 3000.
High frequency stability on temperature and power.
19” mounting brackets are available as an option.
ORDERING DESIGNATIONS
TYPE PRODUCT NO.
BPF 3/1-200-SHT 200000983
BPF 3/2-200-SHT 200001163
BPF 3/3-200-SHT 200001890
SPECIFICATIONS
ELECTRICAL
MODEL BPF 3/1-200-
SHT
BPF 3/2-200-SHT BPF 3/3-200-SHT
FREQ. RANGE 116 - 146 MHz 116 - 146 MHz 116 - 146 MHz
MAX. INPUT
POWER
350 W @
0.5 dB IL
150 W @
2.0 dB IL
350 W @
1.0 dB IL
150 W @
4.0 dB IL
350 W @
1.5 dB IL
150 W @
6.0 dB IL
INSERTION LOSS Adjustable
0.5 - 2.0 dB
Adjustable
1.0 - 4.0 dB
Adjustable
1.5 - 6.0 dB
ATTENUATION See figure 1 See figure 2 See figure 3
IMPEDANCE Nom. 50 Ω Nom. 50 Ω Nom. 50 Ω
SWR
(at resonance)
< 1.5 < 1.5 < 1.5
MECHANICAL
TEMP. RANGE
RH 0-90% non-
condensing
–30° C →
+60° C
–30° C →
+60° C
–30° C →
+60° C
FREQ. STABILITY Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
CONNECTORS N-female N-female N-female
DIMENSIONS ø200 x 600
mm
L:200 x W:400 x
H:600 mm
L:200 x W:600 x
H:600 mm
WEIGHT Approx. 4.6 kg Approx. 10 kg Approx. 14.5 kg
TYPICAL RESPONSE CURVES
Figure 1
TYPICAL RESPONSE CURVES
Figure 2
TYPICAL RESPONSE CURVES
Figure 3
PROCOM A/S reserve the right to amend specifications
without prior notice.
06/05/13

Summary of content (1 pages)